Operation Manual
Software Configuration Strings
Product Reference Guide
235
Standard 2 of 5
Standard 2 of 5 Disable
S2EN 00
Enable
01
Code Length Control Variable
S2LC 00
Fixed
01
Set Length Length 1 (or Min Length) from 1 to 50 characters
S2L1 v
Length 2 (or Max Length) 0 or from 1 to 50 characters
S2L2 v
Check Options
Check Calculation Disable
S2CC 00
Enable
01
Check Tx Disable
S2CT 00
Enable
01
Decoding Options
Minimum Reads One Read
S2MR 01
Two Reads
02
Three Reads
03
Four Reads
04
Decoding Level Disable
S2DL 00
Level 1
01
Level 2
02
Level 3
03
Level 4
04
Level 5
05
Character Correlation Disable
S2CO 00
Enable
01
Stitching Disable
S2ST 00
Enable
01
Industrial 2 of 5
Industrial 2 of 5 Disable
U2EN 00
Enable
01
Code Length Control Variable
U2LC 00
Fixed
01
Set Length Length 1 (or Min Length) from 1 to 50 characters
U2L1 v
Length 2 (or Max Length) 0 or from 1 to 50 characters
U2L2 v
Check Options
Check Calculation Disable
U2CC 00
Enable
01
v
= Hex value from 00 or 02 to 32 representing the decimal number
CODE SELECTION
Description Parameter Value