Operation Manual

Software Configuration Strings
234
Gryphonâ„¢ I GFS4400
Interleaved 2 of 5 (I 2 of 5)
I 2 of 5 Disable
I2EN 00
Enable
01
Code Length Control Variable
I2LC 00
Fixed
01
Set Length
Length 1 (or Min Length) from 2 to 50 characters
(onl
y even numbers)
I2L1 v
Length 2 (or Max Length) from 0 or from 2 to 50 char-
acters (only even numbers)
I2L2 v
Check Options
Check Calculation Disable
I2CC 00
Enable Standard(Mod 10)
01
Enable German Parcel
02
Enable DHL
04
Enable Daimler Chrysler
08
Enable Bosch
10
Enable Italian Post
20
Check Tx Disable
I2CT 00
Enable
01
Decoding Options
Minimum Reads One Read
I2MR 01
Two Reads
02
Three Reads
03
Four Reads
04
Decoding Level Disable
I2DL 00
Level 1
01
Level 2
02
Level 3
03
Level 4
04
Level 5
05
Character Correlation Disable
I2CO 00
Enable
01
Stitching Disable
I2ST 00
Enable
01
Zero Pattern Disable
I2ZP 00
Enable
01
v
= Hex value from 00 or 02 to 32 representing the decimal number
CODE SELECTION
Description Parameter Value