Operation Manual
READING PARAMETERS
Description Parameter Value
Double Read Timeout
20 to 2,550 milliseconds (2.55 seconds) in 10m
s
increments
SNDR f
Illumination Mode Disabled
SPIL 00
Triggered
01
Enabled
02
Operating Modes On Line
SNRM 00
Serial On Line
01
Automatic
02
Automatic (Object Sense)
03
Phase Off Event Trigger Stop
SPTO 00
Timeout
01
Trigger Stop-Timeout
02
Timeout (Scan Active Time) 1 to 255 seconds in 1 second intervals.
SNET h
Serial Start Any string of characters (max 20) between 00-FE
STON i
Serial Stop Any string of characters (max 20) between 00-FE
STOF i
Label Programming Mode Disabled
FAPM 00
Enabled
01
Software Configuration Strings
224
Gryphonâ„¢ I GFS4400
f = Hex value from 02 to FF representing the minimum time between same labels
h = Hex value from 02 to FF representin
g the decimal number (x20 ms)
i = Hex value from 00 to FE representing the ASCII ch
aracter