Operation Manual
INTERFACE SELECTION COMMANDS
Description Command
Restore Current Interface (Custom) Default Configuration
HA00
RS232-STD
HA05
USB-COM
HA47
RS232-Wincor-Nixdorf
HA12
USB-KBD
HA35
USB-KBD-ALT
HA2B
USB KBD-APPLE
HA2C
RS-232 ONLY PARAMETERS
Description Parameter Value
Baud Rate 1200
R2BA 00
2400
01
4800
02
9600
03
19200
04
38400
05
57600
06
115200
07
Parity none
R2PA 00
even
01
odd
02
Data Bits 7
R2DA 00
8
01
Stop Bits 1
R2ST 00
2
01
Handshaking Control RTS
R2HC 00
RTS/CTS
R2HC 01
RTS/Xon/Xoff
R2HC 02
RTS On/CTS
R2HC 03
RTS/CTS Scan Control
R2HC 04
To read a particular parameter setting from the reader, send the
read parameter command without any value. The reader will
respond with its currently configured value.
The Read Application Software Release command is a direct com-
mand that does not require entering Service Mode.
Software Configuration Strings
Product Reference Guide