Operation Manual
Software Configuration Strings
Product Reference Guide
219
Example 1:
1. $S<CR>
Enter Service Mode.
2. $CLFCA02<CR>
W
rite command "Convert to Lower Case" to current configuration.
3. $Ar<CR>
A
pply and Save Configuration to FLASH (permanent memory) and Exit Service Mode.
Each configuration parameter setting removes the condition previously active for that
par
a
meter.
Example 2:
1. $S<CR>
Enter Service Mode.
2. $HA05<CR>
Select RS232 Interface.
3. $Ar<CR>
A
pply and Save Configuration to FLASH (permanent memory) and Exit Service Mode.
Example 3:
1. $+$!<CR>
Read Application Software Release.
Example 4:
Some parameters (ex. Strings) need to insert all the characters (typically 20 Chrs). For example,
to apply the Chr "T" (0x54) as Serial Stop String:
1. $S<CR>
Enter Service Mode
2. $CSTON5400000000000000000000000000000000000000<CR>
Select the string:"T" (54 = T) as Serial Stop Character
.
You must insert all the 20 Chrs (00
= one empty Chr)
3. $Ar<CR>