Operation Manual

Enter/Exit Programming Mode 2D Symbologies
202
Gryphon™ I GFS4400
PDF417 Set Length 2
This feature specifies one of the bar code lengths for PDF417 Length Control. Length 2 is the
maximum label length if in Variable Length
Mode, or the second fixed length if in Fixed Length
Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length
does not include start/stop characters. Characters can be set from 01 to 2,710 characters (pad
with zeroes) in increments of 01. Any value greater than 2,710 will be considered to be 2,710.
See page 255 for detailed instructions on setting this feature.
$CP4L2
Select PDF417 Length 2 Setting
To configure this feature, scan
the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at
left followed by the digits from the Alphanumeric
characters in
Appendix E, Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
bar co
de again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
Length 2 is 2,710 Characters