User Manual
Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE
194
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Datalogic 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length Control. Length 1 is
the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length
Mode. The length includes the barcode’s check and data characters. The length can be set from
2 to 50 characters in increments of two.
Table 14 provides some examples for setting Length 1. See page 302 for detailed instructions on
setting this feature.
Table 14. Datalogic 2 of 5 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
2 Characters 6 Characters 14 Characters 50 Characters
2
Pad with leading zeroes to
yield two digits
02 06 14 50
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT Datalogic 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘2’ ‘0’ and ‘6’ ‘1’ and ‘4’ ‘5’ AND ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE
Select Datalogic 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not
save the entry string. You can then start again at the begin-
ning.
CANCEL
DEFAULT
06 = Length 1 is 6 Characters