User manual
HOST CONFIGURATION STRINGS
173
POWER SAVE
DESCRIPTION STRING
Scan Rate quarter BT0
half BT1
maximum BT2
READING PARAMETERS
DESCRIPTION STRING
Hand-Held Operation software trigger BK0
hardware trigger BK1
automatic BK2
hardware trigger ready BK4
Stand Operation software trigger BU1
hardware trigger BU3
automatic BU0
Hardware Trigger Mode trigger active level BA0
trigger active pulse BA1
Trigger-off Timeout (s) BD00 - BD99
FLASH ON (100 ms) BB001 - BB099
FLASH OFF (100 ms) BB101 - BB199
Reads per Cycle one read BC0
multiple reads BC1
Safety Time (100 ms) BE00 - BE99
Beeper Intensity very low intensity BG0
low intensity BG1
medium intensity BG2
high intensity BG3
Beeper Tone tone 1 BH0
tone 2 BH1
tone 3 BH2
tone 4 BH3
Beeper Type monotone BJ0
bitonal BJ1
Beeper Length long BI0
short BI1
PDF Decoding Recognition Intensity low BW0
high BW1
Good Read Spot - Duration disabled BV0
short BV1
medium BV2
long BV3