User manual

GRYPHON™ BT CORDLESS READING SYSTEMS
166
A HOST CONFIGURATION STRINGS
In this section we provide a description of how to modify the Gryphon™ BT and OM-
Gryphon™ BT configuration using serial strings sent from the Host.
The configuration must be performed in different ways according to the device to be
configured:
OM-Gryphon™ BT
the configuration strings are sent from the Host directly to the device through the
RS232/USB COM interface;
Gryphon™ BT connected with OM-Gryphon™ BT or C-Gryphon
the configuration of the reader when placed onto a cradle is sent from the Host
through the RS232/USB COM interface (RS232 only for C-Gryphon).
When this method is used, the programming sequence format is the following:
Command
Character sequence in following tables
CR$-$+
Carriage return character (0D Hex.)
Enter confi
g
uration environment
Exit and Save configuration
Example:
Beeper tone 1
Beeper low intensity
BG1
$-
CR
Carriage return character (0D Hex.)
Exit and save new configuration
AC410132BH0
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
$+
Enter configuration environment
Multiple command programming sequence:
Each configuration parameter setting removes the condition previously active for that
parameter.
NOTE
The device buffer can contain about 400 characters. If your
programming string goes over this value, you must split it into separate
groups and send each group after a delay of at least 3 seconds to give
the reader time to empty the buffer and interpret the commands.