Datalogic Formula™ www.mobile.datalogic.com World wide Sales Network available from: www.mobile.datalogic.com/contacts Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 Lippo di Calderara di Reno Bologna - Italy Telephone: (+39) 051-3147011 Fax: (+39) 051-3147561 User’s Manual 822000802 (Rev. B) ©2008 Datalogic Mobile S.r.l.
Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Formula™ - User's Manual Ed.: 12/2008 ALL RIGHTS RESERVED The Datalogic name and logo are registered trademarks of Datalogic S.p.A. in many countries. The Formula name is a trademark of Datalogic Mobile S.r.l. All other brand and product names mentioned herein are for identification purposes only and may be trademarks or registered trademarks of their respective owners.
CONTENTS REFERENCES.....................................................................................v Conventions .........................................................................................v Reference Documentation ...................................................................v Services and Support ...........................................................................v SAFETY REGULATIONS ...................................................................vi General Safety Rules ..
3.7.2 Taskbar ............................................................................................. 31 4 4.1 4.2 4.3 4.4 MAINTENANCE ................................................................................ 32 Connecting the Backup Battery......................................................... 32 Charging the Battery Pack ................................................................ 33 Replacing the Battery Pack ...............................................................
REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Formula™ mobile computer. “Mobile computer” and "Formula™" refer to Formula™ mobile computer. “You” refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot a Formula™ mobile computer. REFERENCE DOCUMENTATION For further information regarding Formula™ refer to the Formula™ SwTools CD.
SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Formula™ mobile computer. The user is responsible for any damages caused by incorrect use of the equipment or by inobservance of the indication supplied in this manual. GENERAL SAFETY RULES − Use only the components supplied by the manufacturer for the specific Formula™ being used. − Do not attempt to disassemble the Formula™ mobile computer, as it does not contain parts that can be repaired by the user.
LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE Laser output window This product complies with 21 CFR Subchapter J CAUTION-CLASS 2 LASER LIGHT WHEN OPEN - DO NOT STARE INTO BEAM LASER LIGHT - DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX.
ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mobile computer. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 Subchapter J and EN 60825-1:2001 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device. CAUTION Do not attempt to open or otherwise service any components in the optics cavity.
L'utilizzo di procedure o regolazioni differenti da quelle descritte nella documentazione può provocare un'esposizione pericolosa a luce laser visibile. ATTENZIONE Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti danni riportati dall’occhio umano in seguito ad una esposizione di breve durata, evitare di fissare il raggio laser così come si eviterebbe qualsiasi altra sorgente di luminosità intensa, ad esempio il sole.
Sonne). Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines Beobachters, noch gegen reflektierende Oberflächen zu richten. CAUTION Die Verwendung von Optiksystemen mit diesem Scanner erhöht die Gefahr einer Augenbeschädigung. Zu optischen Instrumenten gehören unter anderem Ferngläser, Mikroskope, Brillen und Vergrößerungsgläser. FRANÇAIS Les informations suivantes sont fournies selon les règles fixées par les autorités internationales et se réfèrent à une correcte utilisation du terminal.
ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 Sección y EN 60825-1:2001. No es necesario abrir el aparato para la instalación, la utilización o la manutención.
Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further information. ITALIANO Prendi contatto con l'autorità competente per la gestione degli apparati a radio frequenza del tuo paese, per verificare eventuali restrizioni o licenze.
FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
WIRELESS AND RADIO FREQUENCIES WARNINGS Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications or attachments could damage the product and may violate laws and regulations. WARNING Most modern electronic equipment is shielded from RF signals. However, certain electronic equipment may not be shielded against the RF signals generated by Datalogic Formula™.
WARNING RF signals may affect improperly installed or inadequately shielded electronic systems in motor vehicles. Check with the manufacturer or its representative regarding your vehicle. You should also consult the manufacturer of any equipment that has been added to your vehicle. WARNING An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the area over the air bag or in the air bag deployment area.
PATENTS This product is covered by one or more of the following patents. Design Pat. AU 310182 S; CN 658612; HK 0601962.6; KR 30-0466667; TW D118829. US Pat. 5,992,740; European Pat. 789,315 B1. Additional patents pending. WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barrato deve essere smaltita, alla fine della sua vita utile, separatamente dai rifiuti urbani.
Information 2002/96/EC aux utilisateurs concernant la Directive Européenne Au terme de sa vie utile, le produit qui porte le symbole d'un caisson à ordures barré ne doit pas être éliminé avec les déchets urbains.
CHINA ROHS POLLUTION CONTROL LOGOS Part name Upper Case Lower Case Touch Panel PCB Board Laser Engine BT Module (Note 1) Pb Toxic or Hazardous Substances and Elements Hg Cd Cr6+ PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O O O O: Indicates that this is a toxic or hazardous substance contained in all of the homogenous materials for this part is below the limit requirement in SJ/T11363-2006.
GENERAL VIEW C K B A H D I G E J F A) B) C) D) E) FSTN Transflective LCD B/W Led Backlight Good Read or User Programmable LED Charging Status LED User Programmable LED Scan Key F) Keyboard G) Radio Status LED H) Laser Safety Label I) Product Label (under battery) J) Battery Pack K) ON/OFF Power Key M N O L L) M) Data Capture/Laser Output Window * DC Charger Connector N) Communication/Charger Connector (through cradle); Serial Connector (through cable) O) Mini USB Communication Connector (throu
xx
INTRODUCTION 1 1.1 1 INTRODUCTION FORMULA™ DESCRIPTION The Formula™ combines fast, accurate barcode scanning and communications options in a small and ergonomic package. It is ready to use out of the box, as the product is provided with a power supply and USB cable. Easy to install, lightweight, and cost-effective, the Formula™ is built to work hard through long shifts. It also makes your work easy and efficient in any condition thanks to its rechargeable Li-Ion battery.
FORMULA™ 1 1.3 PACKAGE CONTENTS The Formula™ package contains: − 1 Formula™ mobile computer − 1 AC/DC power supply USA Plug − 1 AUS Plug Adapter − 1 UK Plug Adapter − 1 EU Plug Adapter − 1 standard Mini USB cable − 1 CD-ROM containing: TM Formula Software Tools installation software The complete documentation and all manuals in PDF format See chapter 3.
INTRODUCTION 1.4 1 INSERTING AN SD CARD Formula™ provides the possibility to add an SD Formula™ storage card. To access the SD card slot and insert the card, proceed as follows: 1. Extract the SD card slot cover from the side of the mobile computer. Then carefully pull it out to unlock its base as shown in the picture below: 2. Insert the card with the written part upward and push it in, aided by the back of a pen, until it clicks into place.
FORMULA™ 1 CAUTION Follow proper ESD precautions to avoid damaging the SD. Proper ESD precautions include, but are not limited to, working on an ESD mat and ensuring that the operator is properly grounded. Do not force the card. If you feel resistance, remove the card, check the orientation, and reinsert it. Do not use the SD card slot for any other accessories. Only MMC/SD with FAT 16 format are supported.
INTRODUCTION 1.5 1 ACCESSORIES Cradles 94A151111 Datalogic Memor™ single cradle with spare battery slot; RS232 and USB communications Batteries 94ACC1326 Datalogic Memor™ Standard Battery Pack (Li-Ion battery pack 1000 mAh@3.7 V) + cover 94ACC1325 Datalogic Memor™ Large Capacity Battery Pack (Li-Ion battery pack 2000 mAh@3.
FORMULA™ 2 2 CONNECTIONS 2.1 USB CONNECTION You can use any standard mini USB cable to directly connect the Formula™ to a host computer to transfer data through the USB interface. A C B Key: A Host computer B Standard mini USB cable C Formula™ The single cradle can be connected to the Host by any standard mini USB cable to transfer data through the USB interface.
CONNECTIONS 2.2 2 RS232 CONNECTION You can use a cable to directly connect the Formula™ to a host computer to transfer data through the RS232 interface. A C B Key: A Host computer B 94A051022 WIN-NET (HRS ST40X-18S-CV) C Formula™ The single cradle can be connected to the Host by any standard 9-pin serial null-modem cable for RS232 communications. Once the Host has been turned on, insert the Formula™ mobile computer into the cradle.
FORMULA™ 2 BLUETOOTH® CONNECTIONS 2.3 ® Bluetooth Formula™ mobile computer models can be connected to a ® Bluetooth host device with a point to point connection.
CONNECTIONS 2.4 2 CONNECTION CABLES The following cable contains its order number.
FORMULA™ 3 3 USE AND FUNCTIONING Formula™ is a lightweight, pocket-sized and fully programmable terminal with 1024 KB of RAM memory to manage large databases and 512 KB of Flash memory for application programs of large dimensions. FORMULATM SOFTWARE TOOLS OVERVIEW 3.1 TM SW TOOLS contains the software for Formula The CD-ROM Formula terminal. It includes: TM Formula Software Tools installation software the complete documentation and all manuals in PDF format. 3.1.
USE AND FUNCTIONING 3 The following table specifies which components can be installed for each type of installation: TM Formula SW TOOLS Component SW Developer’s Toolkits (DS for Formula™) EasyGen™ SysTools™ OLE for Formula™ Ready-To-Use Applications 3.1.
FORMULA™ 3 Software required on Host Computer COMPONENT DS for Formula™ SOFTWARE INSTALLATION Refer to chapter 1.2 of this manual DOCUMENTATION 8051 Keil Compiler V8 Refer to Keil Compiler installation Refer to SW Dev Toolkits Developer’s Manual for further information Refer to compiler documentation SysTools™ Refer to chapter 1.
USE AND FUNCTIONING 3 Host Computer 1./2. develop custom application Host Computer Formula™ 3. download custom application Host Computer Formula™ 4.
3 NOTE 14 FORMULA™ Downloading an executable file not generated with the DS for Formula™ Rel 2.00 or later release can damage the device! Application programs developed for other Formula™ devices are not compatible at execution level, they must be recompiled with Ds for Formula™ Rel 2.00 or later releases. Correct functioning and behaviour of the terminal is guaranteed only under these conditions.
USE AND FUNCTIONING 3.1.4 3 EasyGen™ Component Overview EasyGen™ component is a rapid Application Generator to generate easy and quick Applications running on Formula™ device. A set of ready-to-use EasyGen™ Application examples are installed together with this component. These are the most common application examples (data collection, inventory, goods picking, assisted sales) available in 5 languages (English, French, German, Italian, Spanish).
FORMULA™ 3 Software required on Formula™ Terminal COMPONENT EasyGen™ Interpreter EasyGen™ Application SOFTWARE INSTALLATION The interpreter is installed on the host computer together with EasyGen™ component Examples of applications ready to use are installed on the host computer together with EasyGen™ component installation New applications can be created with EasyGen™. Data transfer 16 SOFTWARE USE DOCUMENTATION 1.
USE AND FUNCTIONING 3 Host Computer Formula™ 1. download EasyGen™ interpreter Host Computer Formula™ 2. download EasyGen™ application Host Computer Formula™ 5.
FORMULA™ 3 3.1.5 SysTools™ Component Overview SysTools™ is an efficient software utility to download application to Formula™ terminal, to exchange data with the terminal and to transfer data to standard ASCII files on the host computer through Serial or USB interface. Refer to the SysTools™ user’s manual for further details. 3.1.
USE AND FUNCTIONING 3 Software required on Formula™ terminal for Standard Mode M1 COMPONENT SOFTWARE USE DOCUMENTATION Standard Mode M1 Executable Applications 1. Configure SysTools™ Startup Mode in Standard/Enhanced Mode 2. Download the Standard Mode executable Files from host computer to Formula™ through SysTools™ 3. Collect data on the terminal 4. Transfer data to PC via SysTools™ Refer to SysTools™ user’s manual for further information Data Transfer Host Computer Formula™ 2.
FORMULA™ 3 Software required on Formula™ terminal for Enhanced Mode M2 COMPONENT SOFTWARE USE DOCUMENTATION Enhanced Mode M2 Executable Applications 1. Configure SysTools™ Startup Mode in Standard/Enhanced Mode 2. Download the Enhanced Mode executable Files from host computer to Formula™ through SysTools™ 3. Create tables for record customization and download tables through SysTools™ Refer to SysTools™ user’s manual for further information Record customization Data Transfer 20 4.
USE AND FUNCTIONING 3 Host Computer Formula™ 2. download Standard Mode M2 Host Computer Formula™ 3. download tables with record format Host Computer Formula™ 5.
FORMULA™ 3 3.2 APPLICATION PROGRAM PALPRO application program is pre-loaded. For further information, refer to Datalogic Formula™ Quick Reference Guide.
USE AND FUNCTIONING 3.3 DELETING PROGRAM 3 AND LOADING THE APPLICATION This procedure allows deleting application programs developed with DS for Formula™. If you want to delete programs provided or developed by EasyGen™, refer to chapter 6 of the EasyGen™ manual. The following procedure causes data to be deleted even if not completed.
FORMULA™ 3 After the boot mode selection the display will show: BOOTSTRAPLOADER ErasPrgFlash Once the deletion procedure is completed, the terminal is ready to receive a new application program.
USE AND FUNCTIONING 3.4 3 DOWNLOADING DATA TO HOST Data can be downloaded from the terminal to the host PC in different ways, depending on the application loaded and on the terminal model. The application software allows to download data onto the host PC by simply inserting the terminal into the cradle, by inserting cables directly into the terminal or by direct operator intervention on the terminal or on the host computer.
FORMULA™ 3 If working with Bluetooth model, the application software can also allow to download data by radio frequency transmission between the terminal and a Bluetooth host device.
USE AND FUNCTIONING 3.5 3 DATA CAPTURE 3.5.1 Laser Data Capture To scan barcodes, point the Formula™ laser model onto the code from a distance within the reading range while pressing the SCAN key. The lighted band emitted by the laser must completely intercept the barcode as shown in the figure below. If enabled, the emission of an acoustic signal will indicate that the scan has taken place correctly. Remove the protective film cover over the Laser Output Window before use.
FORMULA™ 3 3.6 DESCRIPTION OF THE KEYS USING EASYGEN™ It is possible to assign customized functions to function keys depending on the application program developed. The functions described below refer to a terminal using an application program developed with the EasyGen™ Application Generator. Refer to chapter 6 "EasyGen™ Interpreter Program" of the EasyGen™ User's Manual for more details about the key functions.
USE AND FUNCTIONING 3 SHIFT KEY: Enables the entry of alphabetical characters (written in white on the keyboard) when followed by the pressing of a numeric key: for example if you want to enter the alphabetical character “A”, you have to press: +<7>.
FORMULA™ 3 3.7 3.7.1 STATUS INDICATORS LED Status The Formula™ provides four different LEDs signaling the mobile computer status. LED STATUS Good Read and General Purpose (left side) Green It is constant for a configurable time to signal that a successful read has occurred. Green/Red It is also available to the application program. Green constant It is constant once the charging process has been completed. Red constant It is constant while charging.
USE AND FUNCTIONING 3.7.2 3 Taskbar The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status. The first row of the display is used to manage the taskbar and can display the following icons: ICONS DESCRIPTION Time icon Battery icon.
FORMULA™ 4 4 MAINTENANCE Rechargeable backup batteries and battery packs are not initially charged. Therefore the initial operation to perform is to charge them. See below. NOTE CAUTION 4.1 By default, the backup battery is disconnected at the factory to avoid damage due to excessive draining. If it is not connected (through the backup battery switch) and subsequently charged together with the battery pack, all data will be lost when changing the battery pack.
MAINTENANCE 4.2 4 CHARGING THE BATTERY PACK The battery pack autonomy varies according to factors such as the frequency of barcode scanning, RF usage, etc. The battery icon on the Taskbar indicates when the battery pack is low. It is possible to recharge the battery pack by connecting the power supply directly to the Formula™. Alternatively, it is also possible to recharge the battery pack by using the Formula™ single cradle.
FORMULA™ 4 4.3 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Formula™. 2. Use a screw driver to rotate the battery cover screw to the vertical position, then push the battery clips in, as indicated in the figure below. The battery pack cover is now released. 3. Remove the cover and then the battery pack.
MAINTENANCE 4 4. Install the new battery pack, first insert the bottom (contacts) side, then the upper (lock) side as indicated in the following figure: 5. For correct locking, push the battery clips outwards and rotate the screw to the horizontal position.
FORMULA™ 4 To install, charge and/or do any other action on the battery, follow this manual. WARNING The battery pack may get hot, explode, ignite, and/or cause serious injury if exposed to abusive conditions. If the battery pack is replaced with an improper type, there is risk of explosion.
MAINTENANCE 4 In case of leakage of liquid from the battery, avoid contact with liquid the skin or eyes. If the contact occurs, immediately wash the affected area with water and consult a doctor. WARNING Do not solder directly onto the battery pack. Do not expose the battery pack to liquids. Avoid any knocks or excessive vibrations. If the device or the battery is dropped, especially on a hard surface, you should take it to the nearest Authorised Repair Centre for inspection before continuing to use it.
FORMULA™ 5 5 TROUBLESHOOTING PROBLEM CAUSE REMEDY When the button is pressed the terminal does not come on. Flat batteries. Recharge terminal. Batteries completely flat or broken. Replace batteries. When the button is pressed, the terminal displays the message BATTERY LOW and switches itself off. Flat batteries. Recharge terminal. Batteries completely flat or broken. Replace batteries.
TROUBLESHOOTING PROBLEM 5 CAUSE REMEDY The application loaded is not suitable for the terminal in use. The terminal displays the message FAULT CODE P21CO4. Load the correct application program. The terminal displays an error message Other faults. The terminal FAULT CODE.P21CO4. displays an error message other than FAULT CODE P21 CO4. Contact your Datalogic Mobile representative for technical assistance.
FORMULA™ 6 6 6.1 TECHNICAL FEATURES TECHNICAL DATA Formula™ Common Features Electrical Features Power DC Supply Battery Pack 5 V ± 5% 1 cell Li-Ion 1000 mAh@3.7 V (nominal) Alternatively 1 cell Li-Ion 2000 mAh@3.7 V (nominal) Internal Backup Battery Rechargeable Ni-MH 15mAh@.2.
TECHNICAL FEATURES Programming Features Operating System Operating Modes Laser Models Decoded barcodes TBD 6 Proprietary Bootstrap loader; application program Standard 3/9 Extended 3/9 Italian pharmaceutical Interleaved 2/5 ITF 14 Industrial 2/5 Matrix 2/5 UPC - EAN UPC only UPC/EAN + Addon 2 UPC/EAN + Addon 5 UPC-E only UPC 8 only UPC-A & EAN 13 only Codabar (NW7) Monarch (2/7) PAKO Code 128 EAN 128 Delta A IBM MSI Code 93 Zellweger Storagetek GS1 Databar Omnidirectional GS1 Databar Expanded GS1 Databar
FORMULA™ 6 6.
7 7 TEST CODES High Density Codes 0.
FORMULA™ 7 Medium Density Codes 0.
7 Low Density Codes 0.
GLOSSARY Barcode A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in binary form. The general format of a barcode symbol consists of a leading margin, start character, data or message character, check character (if any), stop character, and trailing margin. Within this framework, each recognizable symbology uses its own unique format. Baud Rate A measure for data transmission speed. Bit Binary digit. One bit is the basic unit of binary information.
Light Emitting Diode (LED) A low power electronic light source commonly used as an indicator light. It uses less power than an incandescent light bulb but more than a Liquid Crystal Display (LCD). RAM Random Access Formula™. Data in RAM can be accessed in random order, and quickly written and read. RF Radio Frequency. RTC Real Time Clock. Terminal A Datalogic portable computer product.
INDEX A Accessories; 5 Application Program; 22 Available Models; 1 B Bluetooth® Approval; vi ® Bluetooth Connections; 8 G General Safety Rules; vi General View; xix Glossary; 46 L Laser Class; xi Laser Safety; vii LED Status; 30 C Charging the Batteries; 33 China RoHS Pollution Control Logos; xviii Cleaning the Mobile Computer; 37 Connecting the Backup Battery; 32 Connection Cables; 9 RS232 Direct Connection; 9 Connections; 6 Conventions; v D Data Capture; 27 Laser Data Capture; 27 Datalogic Formula™ Desc
T Taskbar; 31 Technical Data; 40 Technical Features; 40 Test Codes; 43 Troubleshooting; 38 Use and Functioning; 10 W WEEE Compliance; xvi Wireless and Radio Frequencies Warnings; xiv U USB Connection; 6 49
Datalogic Mobile S.r.l. Via S.
Datalogic Mobile S.r.l. Via S.
Datalogic Formula™ www.mobile.datalogic.com World wide Sales Network available from: www.mobile.datalogic.com/contacts Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 Lippo di Calderara di Reno Bologna - Italy Telephone: (+39) 051-3147011 Fax: (+39) 051-3147561 User’s Manual 822000802 (Rev. B) ©2008 Datalogic Mobile S.r.l.