DX6400 QUICK REFERENCE GUIDE NOTE This manual illustrates Local Lonworks network applications. For other types of installations, such as ID-NET™, Pass-Through, Multiplexer Layout, etc., refer to the DX6400 Reference Manual available on the CD. For complete scanner configuration using the Genius™ configuration program refer to the Help On Line. 821001215 (Rev.
DX6400 QUICK GUIDE UPDATES AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Collegarsi a: www.automation.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Cliquez sur : www.automation.datalogic.
DX6400 QUICK GUIDE DX6400 GENERAL VIEW 1 2 Figure A 1 Laser Beam Output Windows 2 Laser Safety Label 3 5 1 2 4 3 1 2 Standard Figure B 1 Programming Keypad 4 Power On LED (Red) 2 TX Data LED (Green) 5 LCD Display 3 4 3 Phase On LED (Yellow) 2 Ethernet Figure C 1 Lonworks 9-pin Male Connector 2 Lonworks 9-pin Female Connector 3 Serial Interface and I/O 25-pin (26-pin) male Connector 4 RJ45 Modular Connector for Ethernet Interface 3
DX6400 QUICK GUIDE CONNECTIVITY Examples of the most common system layouts are shown in this section, for additional layouts refer to the Reference Manual. Local Lonworks Networks CAB-Sxx CAB-610x CBX100** BT-6000 Master Local Host I/O, AUX Slave 1 P.S.* BT-6000 PWR-120 CAB-63xx * P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input. ** CBX100 jumper set to accept scanner power.
DX6400 QUICK GUIDE Fieldbus CAB-610x BT-6000 CBX100** Slave 3 Slave 4 CAB-610x Remote Host I/O, AUX, Encoder*** P.S.* Master* Slave 2 Slave 1 PWR-240 CAB-610x CAB-610x CAB-F0x CAB-63xx CAB-63xx * P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input. ** CBX100 jumper set to accept scanner power. *** Encoder connected to Input 2 (Encoder) input. Synchronized Network with DX6400 Master and 6K Family Slaves - Fieldbus Host BT-6000 CAB-611x PG6000 CAB-Sxx P.S.* P.S.
DX6400 QUICK GUIDE ELECTRICAL CONNECTIONS The details of the connector pins are indicated in the following tables: The table below gives the pinout of the CBX100/CBX500 terminal block connectors.
DX6400 QUICK GUIDE The DX6400 scanner provides a 25-pin (26-pin for Ethernet models) male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals.
DX6400 QUICK GUIDE Ethernet Model RJ45 Modular Connector HUB / SWITCH DX6400 T X+ 1 1 T X- 2 2 RX+ 3 3 n. c. 4 4 n. c. 5 5 RX- 6 6 n. c. 7 7 n. c. 8 8 1 8 RJ45 Female Connector n. c. = not connected APPENDIX TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage Power Consumption Common Communication Interfaces Model-Dependent Communication Interfaces Inputs Ext. Trigger 1, Encoder 2 aux. digital inputs Outputs 3 software programmable digital outputs 15 to 30 Vdc 1.2 to 0.
DX6400 QUICK GUIDE USER INTERFACE LCD Display Keypad LED Indicators 2 lines by 16 characters LCD 3 keys Power On (red) Phase On (yellow) TX Data (green) SOFTWARE FEATURES Readable Codes Interleaved 2/5 Code 39 Standard Codabar Code 128 GS1-128 (ex EAN 128) Code 93 (standard and full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) GS1 DataBar (including Limited and Expanded) Up to 10 codes during one reading phase Up to 128-bytes headers and 128-bytes terminators On Line, Serial On Line, Automatic, Test
DX6400 QUICK GUIDE ACCESSORIES Name Description Part Number Power Supplies PG6002 PG6001 PG6000 PWR-120 PWR-240 PWR-480A Single unit power supply (US) Single unit power supply (UK) Single unit power supply (EU) J-box power unit 110/230 VAC 24 V 120 W J-box power unit 110/230 VAC 24 V 240 W J-box power unit 110/230 VAC 24 V 480 W 93ACC1718 93ACC1719 93ACC1720 93ACC1530 93ACC1070 93ACC1850 Cables and Terminators BT-6000 CAB-6101 CAB-6102 CAB-6105 CAB-6112 CAB-6115 CAB-6305 CAB-6310 CAB-S01 CAB-S02 CAB-
DX6400 QUICK GUIDE MECHANICAL INSTALLATION The DX6400 reader can be positioned and installed in the best way possible as a result of the patented Step-ATM Head feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position.
DX6400 QUICK GUIDE Mount the scanner using the ST-237 mounting bracket which assures an angle of 16°, as indicated in the figure below, in order to obtain an angle of 90° between the two scan lines. This guarantees an omni directional reading of the barcode, if the code label satisfies the ACR™ 4 conditions (see Scanner Reference Manual for details).
DX6400 QUICK GUIDE READING CONDITIONS ANSI Grade B minimum 600 scans/sec per leg The following tables describe the requirements for standard applications. Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.38 14 16 18 20 2/5 Inteleaved 0.50 18 19 21 23 Code Resolution (mm) 0.60 21 22 24 26 1.00 34 35 36 37 Conveyor Speed (m/s) 2.5 22 25 28 39 3 24 27 30 41 2.5 19 21 23 32 3 21 24 26 34 2.5 18 20 21 28 3 20 22 24 30 2.5 24 28 31 44 3 26 30 34 47 2.
DX6400 QUICK GUIDE READING DIAGRAMS DX6400-100-0XX – Resolution: 0.38 mm/15 mils 0 -20 -40 -50 -60 -70 -40 -50 -60 -70 -80 -90 -100 -110 -120 -130 -140 -150 -160 -170 -180 (cm) 0 -40 -30 -30 -10 -20 -10 z 0 0 10 x 20 10 30 40 (in) (cm) Note: x = 0 and z = 0 correspond to the edge of the DX6400 scanner as shown in the figure above. CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 DX6400-100-0XX – Resolution: 0.
DX6400 QUICK GUIDE COMPLIANCE See the DX6400 Reference Manual for the Declaration of Conformity. LASER SAFETY 1 1 2 Figure B Figure A 1 Warning and Device Class Label 1 Laser Safety Label 2 Identification Label The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light.
DX6400 QUICK GUIDE POWER SUPPLY This product is intended to be installed by Qualified Personnel only. - All DX6400 Models: This device is intended to be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25/26-pin connector. CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.