DS6300 INSTALLATION QUICK REFERENCE
CONTENTS DS6300-100-010 MASTER/SLAVES MODELS.......................................................................................................1 DS6300-100-012 ETHERNET MODELS..................................................................................................................5 DS6300-105-0XX OSCILLATING MIRROR MODELS ............................................................................................9 COMMON FEATURES ...............................................................
DS6300-100-010 Master/Slave Models 1 Figure A 1 Laser Beam Output Window 1 5 1 3 4 3 2 2 Figure B Figure C 1 Programming Keypad 4 Power On LED (Red) 2 TX Data LED (Green) 5 LCD Display 1 Main/Aux.
DS6300 QUICK REFERENCE SOFTWARE FEATURES Readable Codes Interleaved 2/5 2/5 compressed Code 39 standard Codabar Code 128 EAN 128 Code 93 (standard & full ASCII) EAN/UPC Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and Terminators 128-byte terminators Operating Modes On Line, Automatic, Test, Config.
DS6300 QUICK REFERENCE The details of the connector pins are indicated in the following table: 25-pin D-Sub Male Connector Pinout Pin 1 20 21 8 22 11 12 16 17 18 19 6 10 14 15 24 9, 13 23, 25 Name Function Shield RXAUX TXAUX OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A OUT 3B EXT_TRIG A EXT_TRIG B IN2A IN2B IN3A IN4A IN_REF VS GND Internally connected by capacitor to chassis Receive data of auxiliary RS232 (referred to GND) Transmit data of auxiliary RS232 (referred to GND) Configurable digital output 1 – positive pi
DS6300 QUICK REFERENCE Connectivity: Point-to-point layout Local Lonworks Network (Single P.S.) Master DS6300 * C-BOX 100 CAB600X CAB610X * C-BOX 100 BTK6000 CAB600X Local Host Slave 1 Local Host P.S. BTK6000 CAB610X PG6000 PWR120 Slave 2 Single P.S. with 3 Readers Local Lonworks Network (Single P.S.) Master CAB600X * C-BOX 100 CAB611X Slave 1 CAB610X PWR120 Slave 2 Local Host CAB610X Slave 3 Single P.S. with more than 3 Readers Local Lonworks Network (Multi P.S.
DS6300-100-012 Ethernet Models 1 Figure A 1 Laser Beam Output Window 3 5 1 3 4 1 2 2 Figure B Figure C 1 Programming Keypad 4 Power On LED (Red) 2 TX Data LED (Green) 5 LCD Display 1 RJ45 Modular Connector for Ethernet Interface 2 Lonworks 9-pin Female Connector 3 Main/Aux.
DS6300 QUICK REFERENCE SOFTWARE FEATURES Readable Codes Interleaved 2/5 2/5 compressed Code 39 standard Codabar Code 128 EAN 128 Code 93 (standard & full ASCII) EAN/UPC Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and Terminators 128-byte terminators Operating Modes Config.
DS6300 QUICK REFERENCE 26-pin D-Sub Male Connector Pinout Pin Name 1 20 21 8 22 11 12 16 17 18 19 6 10 14 15 24 9, 13 23, 25, 26 Shield RXAUX TXAUX OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A OUT 3B EXT_TRIG A EXT_TRIG B IN2A IN2B IN3A IN4A IN_REF VS GND Function Internally connected by capacitor to chassis Receive data of auxiliary RS232 (referred to GND) Transmit data of auxiliary RS232 (referred to GND) Configurable digital output 1 – positive pin Configurable digital output 1 – negative pin Configurable digital
DS6300 QUICK REFERENCE Connectivity: Point-to-point layout Remote Host DS6300 * C-BOX 100 CAB601X PG6000 Ethernet Network Remote Host Ethernet Master CAB601X * C-BOX 100 Slave 1 PWR120 Slave 2 * 8 C-BOX 100 can support up to 2 DS6300 readers. Please contact Datalogic USS Technical Support, if your application requires a multi-slave network.
DS6300-105-0XX Oscillating Mirror Models 1 Figure A 1 Laser Beam Output Window Oscillating mirror models are used when coverage of a large reading area is required, mainly in picket fence applications. The DS6300 scanner mounts a dedicated optic head with integrated oscillating mirror driven by a linear motor. The speed, precision, repeatability, and reliability of this driving technology assure high level performance.
DS6300 QUICK REFERENCE The mirror can be deflected up to 40°. Oscillation with respect to the output window median axis is asymmetrical (see figure below). ° 3 7 .5 40° -2.5° 0° Oscillating Mirror Maximum Aperture and Asymmetry By configuring the oscillating speed up to the maximum value of 19 Hz, raster emulation can be performed for reading fast moving objects. Hz Max.
Common Features Mechanical Installation: TM The DS6300 reader can be positioned and installed in the best way possible as a result of the Step-A-Head feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position.
DS6300 QUICK REFERENCE Focus Adjustment: The DS6300 provides a manual adjustment of the optics to optimize the reading performance by choosing the best focus between two extreme positions. The focus adjustment is continuous and not by step; thus, allowing an optimum adjustment around the selected position. The relative focus positions range from 0 to 100. The adjustment can be simply made through an external screw placed on the back of the optic HEAD and protected by a cap.
DS6300 QUICK REFERENCE 7) Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current operating mode. Focus Adjustment Screw The reader display shows the focus position only when the laser beam is activated. NOTE It is possible to visualize the focus position and the reading percentage on the terminal tool provided by the Genius™ configuration program (see Genius™ Help On-Line for details).
DS6300 QUICK REFERENCE Reading Diagrams: DS6300-100-0XX – Resolution: 0.30 mm/12 mils 0 0 12 300 10 250 8 200 6 150 4 100 2 50 0 0 -2 -50 8 10 12 14 16 18 20 22 24 26 28 30 32 34 (in) 200 250 300 350 400 450 500 550 600 650 700 750 800 850 (mm) Focus Position = 0 Focus Position = 40 -4 -100 -6 -150 -8 -200 -10 -250 Focus Position = 60 -12 -300 (in) (mm) DS6300-100-0XX – Resolution: 0.
DS6300 QUICK REFERENCE Reading Diagrams: DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.20 mm/8 mils 0 0 10 250 8 200 6 150 4 100 2 50 0 0 -2 -50 -4 -100 -6 -150 -8 -200 6 8 10 12 14 16 18 20 22 24 (in) 150 200 250 300 350 400 450 500 550 600 Focus Position = 0 (mm) Focus Position = 40 -10 -250 (in) (mm) DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.
DS6300 QUICK REFERENCE Reading Diagrams: DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.
DS6300 QUICK REFERENCE The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed.
DATALOGIC S.p.A.