Installation manual
TYPICAL LAYOUTS 
79
6
An alternative Pass-Through layout allows the more efficient ID-NET™ network to be used. 
This layout is really an ID-NET Master/Slave Multidata layout which also allows each 
scanner (Master and Slaves) to accept input on the Auxiliary interface, for example to 
connect a device such as a hand-held reader for manual code reading capability.
Each DS4800 transmits its own messages plus any messages received by its Auxiliary 
interface onto the ID-NET™ interface. The Master passes all messages to the Host. 
When On-Line Operating mode is used, the scanner is activated by an External Trigger 
(photoelectric sensor) when the object enters its reading zone. 
Figure 75 – Pass-Through On ID-NET™ Layout 
Host 
1 4 
3 3
Master 
3 
 Main Serial Interface (RS232 or RS485) 
 Auxiliary Serial Interface (RS232) 
 External Trigger (for On-Line Mode) 
 ID-NET™ 
Slave#2 Slave#n 
2
Power 
2