5
5.2.1 RS232 Interface 
The serial interface is used in this case for point-to-point connections; it handles 
communication with the host computer and allows both transmission of code data and the 
programming of the scanner. This is the default setting. 
The following pins are used for RS232 interface connection: 
25-pin
  Name  Function 
2 TX  Transmit Data 
3 RX  Receive Data 
4  RTS  Request To Send 
5  CTS  Clear To Send 
7 GND  Ground 
It is always advisable to use shielded cables. The overall maximum cable length must be 
less than 15 m (49.2 ft). 
DS4800 
7 
4 
5 
3 
GND 
RTS 
CTS 
RX 
TX 
2 
USER INTERFACE 
GND 
CTS 
RTS 
TXD 
RXD 
1 
Chassis 
Figure 50 – RS232 Main Interface Connections Using Hardware Handshaking 
The RTS and CTS signals control data transmission and synchronize the connected devices. 
START
OF 
TRANSMISSION
END
OF 
TRANSMISSION
+ V
RTS
- V
+ V
TX DATA
- V
+ V
CTS
- V
DATA
TRANSMISSION
DATA
TRANSMISSION
C1
C2
C4
C3
C5
TRANSMISSION
STOPPED
ENABLED
DISABLED
ENABLED
IDLE
IDLE
Figure 51 - RS232 Control Signals 
If the RTS/CTS handshaking protocol is enabled, the DS4800 activates the RTS output to 
indicate a message is to be transmitted. The receiving unit activates the CTS input to enable 
the transmission. 