Installation manual
DS4800 REFERENCE MANUAL 
56 
4 
Pulled up to External 
Input Device Power 
Input 
Signal 
Input Device 
Figure 43 - NPN Input 2 Using External Power 
4.5.1 Code Verifier 
If the DS4800 is used as a Code Verifier, the verifier code can be configured in software 
through the Genius™ configuration program. However it is also possible to use one of the 
inputs to trigger when the scanner should store a code read as the verifier code. 
The Code Verifier parameter must be enabled, and the configuration parameters to allow 
correct Code Type reading must be saved to the scanner in order to read the verifier code. 
When the selected input is activated, the next read code will be stored as the verifier code in 
the scanner's non-volatile (Flash) memory. 
For more details see the Verifier Parameters in the "2K/4K Family Software Configuration 
Parameter Guide” Help file". 
4.6 OUTPUTS 
Two general purpose outputs are available. 
CBX100/500
  Function 
+V  Power Source - Outputs 
O1+  Output 1 + 
O1-  Output 1 - 
O2+  Output 2 + 
O2-  Output 2 - 
-V  Power Reference Outputs 
The meaning of the two outputs Output 1 and Output 2 can be defined by the user (No Read, 
Right, Wrong, etc.). Refer to the Genius™ Help On Line. 
By default, Output 1 is associated with the No Read event, which activates when the code 
signaled by the external trigger is not decoded, and Output 2 is associated with the Complete 
Read event, which activates when all the selected codes are correctly decoded. 
The output signals are fully programmable being determined by the configured 
Activation/Deactivation events, Deactivation Timeout or a combination of the two. 