2.5 OSCILLATING MIRROR MODELS 
The DS4800 OM is completely software controlled and software programmable through 
Genius™ which allows adjusting the oscillating frequency and the minimum and maximum 
oscillation angles of two separate reading zones. 
When the oscillating mirror is programmed to read barcode labels at small angles, position 
the reader to assure at least 15° for the Skew angle. This angle refers to the most inclined 
or external laser line, so that all other laser lines assure more than 15° Skew. This avoids the 
direct reflection of the laser light emitted by the reader. 
0°
15°
35°
code 
surface 
-5°
Figure 5 – Oscillating Mirror Skew Angle 
Otherwise, the scanner can be mounted at an angle of inclination of 15° in order to attain 
symmetrical deflection ranges. 
0°
-20°
20°
code 
surface 
15° 
Figure 6 - Oscillating Mirror Reading Position 
In the above case, the zone where the scan line is perpendicular to the reflecting surface 
corresponds to a neutral zone at the center of the reading field. 
NOTE 
By limiting the raster width to the minimum necessary, the number of scans 
on the reading surface is increased. 
The oscillating 
angles have a 
tolerance of ± 2°. 
The oscillating 
angles have a 
tolerance of ± 2°. 