Installation manual

DS4800 REFERENCE MANUAL
110
10
10 TECHNICAL FEATURES
ELECTRICAL FEATURES
Input Power
Supply Voltage 10 - 30 Vdc; (24 Vdc ± 10% for Subzero models)
Maximum Consumption
X0XX (Standard)
X1XX (OM)
XXX5 (Subzero)
0.6 - 0.2 A; 6 W
0.75 - 0.25 A; 7.5 W
1.2 A; 28.8 W @ 24 Vdc
Serial Interfaces
Main Serial Interface SW programmable: RS232; RS485 FD and HD
Baudrate 1200 - 115200
Auxiliary RS232
Baudrate 1200 - 115200
ID-NET™ RS485 Half-Duplex
Baudrate Up to 1 MBaud
Inputs
Input 1 (External Trigger), Input 2 Optocoupled, polarity insensitive
Voltage 10 to 30 Vdc
Current Consumption 12 mA max.
Minimum Pulse Duration 5 ms.
Outputs
Output 1, Output 2 Optocoupled
V
CE
30 Vdc max.
Collector Current 40 mA continuous max.; 130 mA pulsed max.
V
CE saturation
1V max. at 10 mA
Power Dissipation
80 mW max. at 45 C (ambient temperature)
OPTICAL FEATURES
Light Source Semiconductor laser diode
Wave Length In the range 630 to 680 nm
Safety Class Class 2 - EN 60825-1; CDRH
READING FEATURES (Note 1)
Scan Rate (software programmable) 600 to 900 scans/sec
Aperture Angle 50°
Oscillating Amplitude (OM models) 40° ± 2° (-5° to 35°)
Oscillating Frequency (OM models) 0.2 to 20 Hz; 5 Hz max @ 40°; 20 Hz max @ 10°
Maximum Reading Distance
Maximum Resolution
See reading diagrams
ENVIRONMENTAL FEATURES STD and OM Subzero
Operating Temperature (Note 2)
0° to +50 C (+32° to +122 °F) -35° to +50 C (-31° to +122 °F)
(Note 3)
Storage Temperature
-20° to +70 C (-4° to +158 °F) -35° to +70 C (-31° to +158 °F)
Humidity max. 90% non condensing
Vibration Resistance 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
EN 60068-2-6 2 g @ 70 to 200 Hz; 2 hours on each axis
Shock Resistance 30g; 11 ms;
EN 60068-2-27 3 shocks on each axis
Protection Class – EN 60529 IP65
Ambient Light Rejection 30,000 LUX
PHYSICAL FEATURES STD and Subzero OM
Mechanical Dimensions 85 x 101 x 42 mm (3.3 x 4 x 1.7 in) 123 x 117 x 48 mm (4.8 x 4.6 x 1.9 in)
Weight 580 g (20.5 oz.) 780 g (27.5 oz)
Note 1: Further details given in par. 7.3.
Note 2: If the reader is used in high temperature environments (over 40 C), use of the Beam Shutter is advised (see the
Genius™ configuration program) and/or a thermally conductive support (such as the metal bracket provided).
Note 3: The Operating Temperature is guaranteed under the following conditions: no direct ventilation on the scanner, fixed
working environment (no rapid temperature changes). At -35 °C, a 20 min warm-up period is required before the
scanner is ready to read barcodes.