Installation manual
TROUBLESHOOTING 
109
9
TROUBLESHOOTING GUIDE 
Problem  Suggestions 
Reading: 
Not possible to read the 
target barcode (always 
returns No Read) or the 
Auto Setup procedure 
Fails. 
Check synchronization of reading pulse with object to read: 
Is the scan line correctly positioned? 
Place barcode in the center of scan line and run Test mode 
(selectable by Genius™ as an Operating Mode). If you still have 
trouble, check the following: 
  Is the reading distance within that allowed (see reading 
diagrams)? 
  Is the scanner correctly focused? 
  Is the Tilt angle too large? 
  Is the Skew angle less than 15° (direct reflection)? 
  Choose the Code Definition branch and enable different 
Code Symbologies (except Pharmacode). Length = Min 
and Max (variable). 
  Is the Bar Code quality sufficient? 
If you had no success, try to perform the test using the 
BARCODE TEST CHART included with the product. 
Communication: 
Device is not 
transmitting anything to 
the host 
  Is the serial cable connected? 
  Is the correct wiring respected? 
  Are serial host settings equivalent to the serial device 
setting? 
  If using CBX, be sure the RS485 termination switch is 
positioned to OFF. 
Communication: 
Data transferred to the 
host are incorrect, 
corrupted or incomplete 
  In the Genius™ program select the Data Communication 
Settings/Data Format/Standard Parameters branch and 
check the Header, Separators, and Terminator values 
  Also check the Code Field Length and Fill Character values. 
  Are the COM port parameters correctly assigned? 
Communication: 
Always returns the 
Reader Failure 
Character (<BEL> char 
as default) 
  Contact your local Datalogic office or Datalogic Partner or 
ARC, because either a Motor or Laser failure has occurred. 
  Note the exact model and Serial Number of the device. 
How do I obtain my 
units’ serial 
numbers? 
  The device’s serial number is printed on a label that is affixed 
to the body of the reader. 
  Serial numbers consist of 9 characters: one letter, 2 
numbers, and another letter followed by 5 numbers. 