Installation manual
READING FEATURES
93
7
7.3 PERFORMANCE
The reading performance of the DS4800 scanner depends in part on the focus position
setting.
Focus Max Code Resolution Speed
mm (mils) scans/s
F = 30 Near 0.20 (8) 800
F = 40 Medium 0.30 (12) 800
F = 60 Far 0.38 (15) 800
1000 (Standard Models)
Focus Reading Distance
F = 30 Near 21 cm (8.3 in) - 47 cm (18.5 in) on 0.50 mm (20 mils) codes
F = 40 Medium 27 cm (10.6 in) - 68 cm (26.8 in) on 0.50 mm (20 mils) codes
F = 60 Far 40 cm (15.7 in) - 100 cm (39.4 in) on 0.50 mm (20 mils) codes
1100 (OM Models)
Focus Reading Distance
F = 30 Near
20 cm (7.9 in) - 43 cm (16.9 in) on 0.50 mm (20 mils) codes
F = 40 Medium
26 cm (10.2 in) - 64 cm (25.2 in) on 0.50 mm (20 mils) codes
F = 60 Far
39 cm (15.4 in) - 95 cm (37.4 in) on 0.50 mm (20 mils) codes
1005 (Subzero Models)
Focus Reading Distance
F = 30 Near
22 cm (8.7 in) - 45 cm (17.7 in) on 0.50 mm (20 mils) codes
F = 40 Medium
28 cm (11 in) - 65 cm (25.6 in) on 0.50 mm (20 mils) codes
F = 60 Far
41 cm (16.1 in) - 96 cm (37.8 in) on 0.50 mm (20 mils) codes
1105 (OM Subzero Models)
Focus Reading Distance
F = 30 Near
21 cm (8.3 in) - 41 cm (16.1 in) on 0.50 mm (20 mils) codes
F = 40 Medium
27 cm (10.6 in) - 61 cm (24 in) on 0.50 mm (20 mils) codes
F = 60 Far
40 cm (15.7 in) - 90 cm (35.4 in) on 0.50 mm (20 mils) codes
Refer to the diagrams in par. 7.4 for further details on the reading features.
For Standard and OM models, these
diagrams are taken on various resolution sample codes
at a 25 C ambient temperature and depend on the conditions listed under each diagram.
Subzero model diagrams are based on an ambient temperature of -35 °C and depend on the
conditions listed under each diagram.










