Installation manual
READING FEATURES 
91
7
7.2  LINEAR CODE READING 
The number of scans performed on the code by the DS4800 and therefore the decoding 
capability is influenced by the following parameters: 
  number of scans per second 
  code motion speed 
 label dimensions 
  scan direction with respect to code motion 
At least 5 scans during the code passage should be allowed to ensure a successful read. 
7.2.1 Step-Ladder Mode 
If scanning is perpendicular to the code motion direction (Figure 90), the number of effective 
scans perfor
med by the reader is giv
en by the following formula: 
SN = [(LH/LS) 
*
 SS] – 2  Where:  SN =  number of effective scans 
  LH  =  label height (in mm) 
  LS  =  label movement speed in (mm/s) 
  SS  =  number of scans per second 
Figure 90 - "Step-Ladder" Scanning Mode 
For example, the DS4800 (800 scans/sec.) for a 25 mm high code moving at 1250 mm/s 
performs: 
[(25/1250) 
*
 800] - 2 = 14 effective scans. 
Direction of code 
movement at LS speed
Laser beam 
DS4800 
LH