Installation manual

DATALOGIC DS1100
Installation - 2.9
An anti-disturbance hardware filter is implemented on the External Trigger
input (about 1 millisecond delay).
An additional 15 ms (typical) delay can be implemented through a dedicated
software parameter (refer to WinHost Help On Line).
2.3.5 Outputs
The following pins are present on the connector of the scanner:
Pin Name Function
8 OUT1+ Output 1 +
12 GND I/O Reference
11 OUT2+ Output 2+
22 GND I/O Reference
The meaning of the two outputs OUT1 and OUT2 can be defined by the user.
Refer to the Winhost Help On Line.
By default, OUT1 is the No Read signal, which activates when the code
signalled by the external trigger is not decoded, and OUT2 is the Right
output, which activates when the code is correctly decoded.
USER INTERFACE
Vext 50 Vdc max., 50 mA max.
DS1100
8/11
12/22
OUT 1 + / OUT 2 +
GND
Ground
Figure 2.11 - DS1100 Output connections
These outputs are both level or pulse configurable.
2.4 POSITIONING
The DS1100 scanner is able to decode moving barcode labels at a variety of
angles, however significant angular distortion may degrade reading