User manual

Label ID Enter/Exit Programming Mode
Product Reference Guide
77
Individually Set Label ID
This feature configures a Label ID individually for a single symbology. See Label ID: Set
Individually Per Symbology, starting on page 266 for detailed instructions on setting this
feature.
Label ID Control
This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given
symbology type.
DEFAULT
$CIDCO00(CR)
Label ID Transmission = Disable
$CIDCO01(CR)
Label ID Transmission = Enable as Prefix
$CIDCO02(CR)
Label ID Transmission = Enable as Suffix