Gryphon™ I GD44XX
/
GBT4400
Codabar Set Length 2
This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length
Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed
length if in Fixed Length Mode. The length includes the bar code’s start, stop, ch
eck and data
characters. The length must include at least one data character.
The length can be set from 3 to 50 characters. A setting of
0 specifies to i
gnore this length (only
one fixed length).
Table 14 provides examples for setting Length 2. See page 259 for detailed instructions on
setting this feature.
Table 14. Codabar Length 2 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (and pad
with le
ading ze
roes)
00 Ignore This
Length
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODABAR LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CCBL2
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters