User manual

Enter/Exit Programming Mode
100
Gryphon™ I GD44XX
/
GBT4400
Aiming Duration Timer
Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger
single mode.The range for this setting is from 1 to 255 seconds in 1-second increments. See
page 274 in “References” for a description of this feature.
DEFAULT
LSTM00
Aiming Off After Decoding
LSTM
Set Aiming Duration Timer
To configure, scan the ENTER/EXIT PROGRAMMING
MODE bar
code above, then the barcode at left followed
by the digits from the Alphanumeric characters in
Appendix D, Keypad representing your desired char-
acter(s). End by scanning the ENTER/EXIT barcode
.
Make a mistake? Scan the CANCEL bar code to abort
and not sav
e the entry string. You can then start again at
the beginning.
~
CANCEL
Green Spot Duration
Specifies the duration of the good read pointer beam after a good read.
$CLSSP00(CR)
Green Spot Duration = Disable (Green Spot is Off)
$CLSSP01(CR)
Green Spot Duration = Short (300 msec)
DEFAULT
$CLSSP02(CR)
Green Spot Duration = Medium (500 msec)
$CLSSP03(CR)
Green Spot Duration = Long (800 msec)