Gryphon™ I GBT4400 General Purpose Handheld Area Imager Bar Code Reader with Bluetooth® Wireless Technology Quick Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Table of Contents Software Product Policy .............................................................................4 Customers Under Software Support ..........................................4 Description .....................................................................................................5 Setting Up the Reader ................................................................................6 Positioning the Base Station .........................................................
FCC RF Radiation Exposure Statement ........................ 48 Canadian Notice .............................................................................. 48 Power Supply ................................................................................... 48 Imager Labeling .............................................................................. 49 Aiming System...................................................................... 49 WEEE Statement ..................................................
Datalogic Scanning, Inc. GRYPHON™ PRODUCT SERIES END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product's operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will be deemed to have accepted the terms and conditions of this Agreement.
3.2 3.3 instead may elect to notify End User that End User is deemed to have ordered and accepted a license for each breaching use. End User shall pay Datalogic the applicable list price for such licenses as of the date of such breach. End User shall not sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer the Datalogic Product to any third party unless such third party agrees with Datalogic in writing to be bound by the terms and conditions of this Agreement.
. Infringement. 7.1 7.2 7.3 7.
Software Product Policy 11. General Provisions. 11.1 11.2 11.3 11.4 11.5 Entire Agreement; Amendment. This document contains the entire agreement between the parties relating to the licensing of the Software and supersedes all prior or contemporaneous agreements, written or oral, between the parties concerning the licensing of the Software. This Agreement may not be changed, amended, or modified except by written document signed by Datalogic. Notice.
Gryphon™ I GBT4400 Description With rich feature sets and extensive options, the Gryphon™ product series from Datalogic Scanning represents the premium level of data collection equipment for general purpose applications. The Gryphon GBT4400 readers have enhanced optics with improved motion tolerance allowing codes placed on fast moving objects to be easily and quickly captured, creating the ideal reader for tasks requiring high throughput like those found in retail and light industrial environments.
Setting Up the Reader Setting Up the Reader Follow the steps below to connect and get your reader up and communicating with its host. 1. 2. 3. 4. 5. Configure the Base Station starting on this page. Charge the Batteries (see page 14). Link to the Base Station (see page 19). Select the Interface Type (see page 20). Configure the Reader starting on page 32 (optional, depends on settings needed).
Setting Up the Reader 1. Insert the appropriate parts for the desired base station position, as shown below. Standing, Horizontal or Vertical 2. Horizontal Only Using your thumbs, push open the plastic tabs on the bottom of the base to free the wing holders.
Connecting the Base Station 3. The stand can now be repositioned in either horizontal or standing position. Horizontal Standing Connecting the Base Station Figure 1 on page 9 shows how to connect the Base Station to a terminal, PC or other host device. Turn off the host before connection and consult the manual for that equipment (if necessary) before proceeding. Connect the interface cable before applying power to the Base Station. The Gryphon GBT can also be Powered by the Terminal.
Connecting the Base Station Figure 1. Connecting the Base Station Wall plug Connector I/F Cable AC/DC Adapter DC Power Cord Base Station Securing the DC Power Cord (Optional) The DC power cord for the adapter can be secured to the bottom of the base in order to maximize the mechanical retention of the cable itself. The routing of the power cord can be changed to accommodate base station positioning: horizontal, stand or wall mount.
Connecting the Base Station Figure 3. Arrows showing routing Host Connection: Verify before connection that the reader’s ca- ble type is compatible with your host equipment. The Gryphon I GBT4400 can be set up to require a PIN code when connecting to the host. If you are adding new equipment to a system that uses a custom security PIN, please see the PRG for information before proceeding. Most connections plug directly into the host device as shown in Figure 4 on page 10.
Connecting the Base Station Power Connection: Plug the AC Adapter into an approved AC wall socket with the cable facing downwards (as shown in Figure 1) to prevent undue strain on the socket. Disconnecting the Cable: To detach the cable, insert a paper clip or similar object into the hole on the base, as shown. Figure 5. Disconnecting the Cable Insert Paper Clip System and Network Layout Typical Setup with Cradle and Host Figure 6.
Connecting the Base Station Using the BC40xx™ Radio Base Radio Base LEDs LEDs on the Gryphon Base provide information about the Base as well as battery charging status, as shown in Figure 7. Figure 7. Gryphon Base LEDs YELLOW LED BUTTON RED LED — GREEN LED Table 1. Radio Base LEDs LED STATUS Power on / Data Yellow On = Base is powered Yellow Blinking = Base receives data and commands from the Host or the Reader. Charging Red On = the Battery is charging.
Cleaning Cleaning Exterior surfaces and scan windows exposed to spills, smudges or debris accumulation require periodic cleaning to ensure best performance during scanning operations. Contacts on the scanner and the base should also be cleaned as needed to ensure a good connection. Always use a soft, lint-free cloth or lens tissue dampened with isopropyl alcohol (or equivalent) or water-based window cleaner.
Charging the Batteries Charging the Batteries To charge the battery, simply insert the Gryphon into the base. When the scanner is fully seated in the cradle, it will sound a “chirp” to indicate that the cradle has detected the scanner connection. The LEDs on the base (shown in Table 1) will indicate the status of the battery. Before using the Battery, read “Battery Safety” in the following section. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance.
Charging the Batteries WARNING CAUTION CAUTION CAUTION In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye. Always charge the battery at 32° – 104°F (0° - 40°C) temperature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller.
Charging the Batteries The typical manufacturer advertised useful life of LI batteries is one-three years, depending on usage and number of charges, etc., after which they should be removed from service, especially in mission critical applications. Do not continue to use a battery that is showing excessive loss of capacity, it should be properly recycled / disposed of and replaced.
Charging the Batteries 3. Carefully lift out the gold contacts circuit, and remove the battery holder cap while letting the white connector pass through the hole in the battery holder (as shown below). Pass-through hole Gold contacts circuit 4. 5. Remove the old battery from its place (if present), and insert the new battery in the same position. Replace the battery holder cap, plug in the connector and return the contacts circuit to its previous location.
Using the Gryphon™ I GBT4400 Using the Gryphon™ I GBT4400 The Gryphon™ I GBT4400 normally functions by capturing and decoding codes. The reader is equipped with an internal motion-sensing function which activates the aiming system on device motion. The intelligent aiming system indicates the field of view which should be positioned over the bar code: Aiming System Relative Size and Location of Aiming System Pattern Linear bar code 2D Matrix symbol A red beam illuminates the label.
Linking the Reader Linking the Reader Link Datalogic RF Devices to Base For RF devices, before configuring the interface it is necessary to link the handheld with the base. To link the handheld and the base, either press the trigger to wake it, or simply mount into the base to wake up for operation. If the reader was previously linked to another base, you must first scan the Unlink bar code before re-linking to the new base. Unlink Link Scanner to Bluetooth Adapter 1. 2. 3. 4.
Power Off Power Off Scan the bar code below to shut off power to the BT handheld until the next trigger pull. PowerOff Selecting the Interface Type Upon completing the physical connection between the reader and its host, proceed directly to Interface Selection on page 20 for information and programming for the interface type the reader is connected to (for example: RS-232, Keyboard Wedge, USB, etc.) and scan the appropriate bar code to select your system’s correct interface type.
Selecting the Interface Type RS-232 RS-232 standard interface Select RS232-STD RS-232 Wincor-Nixdorf Select RS232-WN RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS USB COM to simulate RS-232 standard interface Select USB-COM-STDa a. Download the correct USB COM driver from www.datalogic.
Selecting the Interface Type IBM IBM-46xx Port 5B reader interface Select IBM-P5B IBM-46xx Port 9B reader interface Select IBM-P9B USB-OEM USB-OEM (can be used for OPOS/UPOS/JavaPOS) Select USB-OEM 22 Gryphon™ I GBT4400
Selecting the Interface Type Keyboard Interface Use the programming bar codes to select options for USB Keyboard and Wedge Interfaces.
Selecting the Interface Type KEYBOARD (continued) PC/XT w/Standard Key Encoding Select KBD-XT Keyboard Wedge for IBM Terminal 3153 Select KBD-IBM-3153 Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard Select KBD-IBM-M Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard Select KBD-IBM-MB USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Keyboard for Apple computers Select USB-KBD-APPLE 24 Gryphon™ I GBT4400
Selecting the Interface Type KEYBOARD (continued) Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Select KBD-DIG-VT USB Keyboard with standard key encoding Select USB Keyboard WAND EMULATION Wand Emulation Select WAND Scancode Tables Reference the Gryphon™ PRG for information about control character emulation which applies to keyboard interfaces. Country Mode This feature specifies the country/language supported by the keyboard.
Selecting the Interface Type COUNTRY MODE ENTER/EXIT PROGRAMMING MODE Country Mode = U.S.
Selecting the Interface Type COUNTRY MODE (Continued) Country Mode = Czech* Country Mode = Denmark* Country Mode = France Country Mode = Germany Country Mode = Hungary* Country Mode = Italy *Supports only the interfaces listed in the Country Mode feature description Quick Reference Guide 27
Selecting the Interface Type COUNTRY MODE (Continued) Country Mode = Japanese 106-key* Country Mode = Norway* Country Mode = Poland* Country Mode = Portugal* Country Mode = Romania* Country Mode = Spain *Supports only the interfaces listed in the Country Mode feature description 28 Gryphon™ I GBT4400
Selecting the Interface Type COUNTRY MODE (Continued) Country Mode = Sweden Country Mode = Slovakia* Country Mode = Switzerland* *Supports only the interfaces listed in the Country Mode feature description Quick Reference Guide 29
Selecting the Interface Type Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected.
Selecting the Interface Type Numlock This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard.
Programming Programming The reader is factory-configured with a set of standard default features. After scanning the interface bar code from the Interfaces section, select other options and customize your reader through use of the programming bar codes available in the Product Reference Guide (PRG). Check the corresponding features section for your interface, and also the Data Editing and Symbologies chapters.
Reading Parameters Reading Parameters Point the reader at the target and pull the trigger to enable the aiming system and the illuminator (red beam) to capture and decode the image. The aiming system will briefly switch off during the acquisition time and if no code is decoded will switch on again before the next acquisition. The illuminator will remain on until the symbol is decoded. As you read code symbols, adjust the distance at which you are holding the reader.
Reading Parameters Good Read Green Spot Duration Successful reading can be signaled by a good read green spot. Use the bar codes below to specify the duration of the good read pointer beam after a good read.
Scan Modes Scan Modes The imager can operate in one of several scanning modes. Trigger Single — When the trigger is pulled, scanning is activated until one of the following occurs: - a programmable duration1 has elapsed - a label has been read - the trigger is released This mode is associated with typical handheld reader operation. Trigger Hold Multiple — When the trigger is pulled, scanning starts and the product scans until the trigger is released or a programmable duration1 has elapsed.
Scan Modes SCAN MODE ENTER/EXIT PROGRAMMING MODE Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashing Scan Mode = Always On Scan Mode = Stand Mode 36 Gryphon™ I GBT4400
Scan Modes Pick Mode Pick Mode is a Decoding and Transmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowledged or transmitted to the host. It is active only while the scanner is in Trigger Single mode. If the scanner switches to a different Read Mode, Pick Mode is automatically disabled. This feature is not compatible with Multiple Labels Reading in a Volume. See the PRG for more information.
Technical Specifications Technical Specifications The following table contains Physical and Performance Characteristics, User Environment and Regulatory information. Physical Characteristics Color White/Gray Black/Gray Dimensions Height 7.1”/181 mm Length 3.9”/100 mm Width 2.8”/71 mm Weight (without cable) Approximately 8.7 ounces/246 g (reader with display) 8.
Technical Specifications Depth of Field (Typical)a Symbology SR: HD: Code 39 5mil: 1.6” -7.5” (4.0 -19cm) 10mil: 0.4” - 11..8” (1.0 - 30cm) 20mil: up to 17.7” (up to 45cm) 3mil: 0.9” - 3.6” (2.4 - 9.1cm) 5 mil: 0.3” - 4.5” (0.8 -11.3cm) EAN 7.5mil: 0.5” - 10.6” (2.0 - 27cm) 13mil: 0.6” - 15.7” (1.5 - 40cm) 7.5mil: 0” - 5” (0 - 12.7cm) 13mil: 4.3” - 6.8” (1.1- 17.2cm) PDF-417 6.6mil: 1.0” - 5.9” (2.5 - 15cm) 10mil: 0.2” - 8.6” (0.5 - 22cm) 15mil: 0.6” - 13.4” (1.5 - 34cm) 4mil: 0.7” - 2.7” (1.
Technical Specifications Decode Capability 1D Bar Codes UPC/EAN/JAN (A, E, 13, 8); UPC/EAN/JAN (including P2 /P5); UPC/EAN/JAN (including; ISBN / Bookland & ISSN); UPC/EAN Coupons; Code 39 (including full ASCII); Code 39 Trioptic; Code39 CIP (French Pharmaceutical); LOGMARS (Code 39 w/ standard check digit enabled); Danish PPT; Code 32 (Italian Pharmacode 39); Code 128; Code 128 ISBT; Interleaved 2 of 5; Standard 2 of 5; Interleaved 2 of 5 CIP (HR); Industrial 2 of 5; Discrete 2 of 5; Datalogic 2 of 5 (Chi
Technical Specifications Drop Specifications Scanner withstands 18 drops from 1.8 meters (5.9 feet) to concrete Ambient Light Immunity Up to 100,000 Lux Contaminants Spray/rain Dust/particulates IEC 529-IP52 (scanner only) ESD Level 16 KV Regulatory Electrical Safety UL 60950, CSA C22.2 No.
LED and Beeper Indications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The following tables list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and so may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming bar code labels.
LED and Beeper Indications Indication Green Spota flashes momentarily Image Capture Description LED Beeper Upon successful read of a label, the software shall turn the green spot on for the time specified by the configured value.
LED and Beeper Indications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. INDICATION DESCRIPTION LED Label Programming Mode Entry A valid programming label has been scanned. LED blinks continuously BEEPER Reader sounds four low frequency beeps. N/A Reader sounds three times at lowest frequency and current volume. N/A Reader sounds one short beep at highest frequency and current volume.
Error Codes Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found.
Base Station Indications Base Station Indications Indication LEDS Power-up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is not established Yellow LED blinking ~1Hz Data/labels are transmitted to the HOST Yellow LEDs turned off for 100mSec Programming Mode Yellow LED blinks quickly Configuration alignment with the HH is in progress Red LED blinks quickly Battery charger in progress Red LED on Battery charger complete Green LED on Battery charger error Gr
Statement of Agency Compliance Regulatory Information All versions of the reader are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to equipment, not expressly approved by Datalogic could void the user's authority to operate the equipment. Statement of Agency Compliance This device complies with part 15 of the FCC Rules.
Statement of Agency Compliance FCC RF Radiation Exposure Statement Exposure to Radio-Frequency Radiation CAUTION To comply with FCC RF exposure compliance requirements, for mobile configurations, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter.
Statement of Agency Compliance Imager Labeling Sample labels are shown for illustrative purposes only. Please view the labels on your product for actual details, as they may vary from those depicted. Scanner Regulatory Label Contains FCC IC: 3862A-DL ID: 09NDLBTMCX BTMCX See product manual and package for patent listin g. N26 3 LISTED RY ACCESSOU I.T.E., .3KR Base Station Label Aiming System LASER LIGHT - DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT OUTPUT RADIATION 1 mW AVG.
Statement of Agency Compliance I D F E LA LUCE LASER È VISIBILE ALL'OCCHIO UMANO E VIENE EMESSA DALLA FINESTRA INDICATA NELLA FIGURA. DIE LASER-STRAHLUNG IST FÜR DAS MENSCHLICHE AUGE SICHTBAR UND WIRD AM STRAHLAUS TRITTSFENSTER AUSGESENDET (SIEHE BILD) LE RAYON LASER EST VISIBLE À L'OEIL NU ET IL EST ÉMIS PAR LA FENÊTRE DÉSIGNÉE SUR L'ILLUSTRATION DANS LA FIGURE A LUZ LÁSER ES VISIBLE AL OJO HUMANO Y ES EMITIDA POR LA VENTANA INDICADA EN LA FIGURA.
Statement of Agency Compliance The product utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid allowing the laser beam to hit the eye of an observer, even through reflective surfaces such as mirrors, etc.
Statement of Agency Compliance Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs-Arbeiten zu öffnen. ACHTUNG Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschreiben werden, können ein gefährliches Laserlicht verursachen. Der Produkt benutzt eine Laserdiode.
Statement of Agency Compliance ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS LÁSER ESTÁNDAR PARA LA SEGURIDAD Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1. No es necesario abrir el aparato para la instalación, la utilización o la manutención.
Statement of Agency Compliance WEEE Statement Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
Warranty Warranty Datalogic warrants to Customer that Datalogic's products will be free from defects in materials and workmanship for a period of one year from product shipment. This warranty does not extend to batteries and cables. As consumable items batteries and cables carry a 90 day warranty from time of purchase for DOA (dead on arrival) defects.
Ergonomic Recommendations Ergonomic Recommendations In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you CAUTION are adhering to your company’s safety programs to prevent employee injury.
Services and Support Services and Support Datalogic provides several services as well as technical support through its website. Log on to www.scanning.datalogic.com and click on the links indicated for further information. Products Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities, including: • Datalogic Aladdin™, a multi-platform utility program that allows device configuration using a PC.
Services and Support NOTES 58 Gryphon™ I GBT4400
DECLARATION OF CONFORMITY EC-063 Rev.: 0 Pag.: 1 di 1 10 Datalogic Scanning, Inc.
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Latin America Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.