User`s manual
DL TCL™
48
4
- Terminator key: defines the key to be pressed to include a terminator
character in the output data format. Possible selections are:
None = no terminator added to the data string
Enter = terminator ASCII value is 13
Tab = terminator ASCII value is 08
Field Exit = special key available in the AS400 emulation
(only for IBM5250/3270 terminal emulation).
- Code Type: opens further masks listing all available code types for the
connected terminal:
Code 39 standard UPC-A MSI
Code 39 full ASCII UPC-E Code 11
Code 39 CIP EAN-8 Code 93
Italian Pharmaceutical EAN-13 PDF-417
Interleaved 2/5 Codabar Micro PDF
Industrial 2/5 Code 128
Matrix 2/5 EAN-128
The selection of a code type within the mask is signaled by
displaying the code in reverse video.
- Clrbefore SCAN: This “Clears Before Scan” key is only available in
connection with an AS400 Host. It defines whether clearing
the input field before sending the code barcode read.
Printer
It defines the type of printer port through which sending data from the terminal to the
printer.