User Manual

Cleaning Procedure
Product Reference Guide
19
Cleaning electrical contact surfaces
Regular cleaning of electrical contacts is needed to guarantee a correct
recharging of the battery. Both scanner and cradle contacts should be cleaned.
In case spills, smudges or debris accumulate on the cradle and/or the scanner,
proper operation could be affected and a periodical cleaning is recommended
as follows.
Avoid the use of brushes or any other hard tool to remove grime from electrical
c
ontacts, since these may damage or scratch the contact's plating.
Scanner Contacts
Use a soft dry cloth to clean the contact area and the plastic surface
around the contacts.
Be sure to remove dust, dirt and any cloth res
idue.
If the level of grime is significant, it is suggested the use of a soft white or
pink pencil eras
er to gently rub the contacts. Motion can be along both the
green and yellow directions.
Be sure to remove the rubber residuals by gently blowing them off with
clean compressed air.
CAUTION
Be careful when using compressed air: protect yourself with goggles and
point the nozzle far from eyes and not too close to the scanner surface.
Read previously the warning label on the spray can.
Cradle Contacts
Use a soft dry cloth to clean the contact area and the plastic surface
around the contacts.
Particular attention must be paid to
remove dust, dirt and any cloth resi-
due. Do not allow this material t
o fall again onto the contacts.
It is suggested the use of a soft white or pink pencil eraser to gently rub
th
e contacts. Cradle contacts should be cleaned with a motion along the
yellow direction.