User Manual
References
240 RIDA™ DBT6400
Label ID: Set Individually Per Symbology
To configure a Label ID individually for a single symbology:
1. Scan the ENTER/EXIT barcode.
2. Select Label ID position as either BEFORE (Enabl
e as Prefix) or AFTER
(Enable as suffix) by scanning the appropriate barcode in the section
"Label
ID Control"
on page 71. Reference Figure 4 for Label ID positioning options
if multiple identification features are enabled.
3. Scan a barcode to select the symbology for which you wish to configure a
cu
stom Label ID from the section
Case Conversion, starting on page 78
.
4. Determine the desired character(s) (you may choose up to three) which will
re
present the Label ID for the selected symbology.
5. Turn to the
ASCII Chart on page 303
on the inside back cover of this manual
and find the equivalent hex digits associated wit
h your choice of Label ID.
For example, if you wish to select an equal sign (=) as a Label ID, the chart
indicates its associated hex characters as 3D. Turn to
Keypad, starting on
page 295
and scan the barcodes representing the hex characters deter-
mined. For the example given, the charact
ers ‘3’ and ‘D’ would be
scanned. More examples of Label ID settings are provided in
Table 12
.
NOTE
If you make a mistake before the last
character, scan the CANCEL bar-
code to abort and not save the entry
string. You can then start again at
the beginning.
6. Scan the ENTER/EXIT barcode to exit Label ID entry.
7. Scan the ENTER/EXIT barcode once again to exit Programming Mode.
This completes the steps to configure
a Label ID for a given symbology.
Figure 4. Label ID Position Options