User Manual
Enter/Exit Programming Mode Code 11
164 RIDA™ DBT6400
Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding
for the Code 11 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
Code 11 Length Control = Variable Length
Code 11 Length Control = Fixed Length
Code 11 Set Length 1
This feature specifies one of the barcode lengths for Code 11 Length Control on
page 164. Length 1 is the minimum
label length if in Variable Length on page
164 Mode, or the first fi
xed length if in Fixed Length on page 164 Mode. Length
includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters. See "Set Length 1" on
page 248
for more detailed programming in
structions.
$CC1LC00
$CC1LC01
$CC1L1
Select Code 11 Set Length 1 Setting
To configure this feature, scan the ENTER/EXIT barcode
above, then the barcode at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL










