Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)
146 RIDA™ DBT6400
I 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for I 2 of 5 Length Control on
page 145. Length 1 is the minimum
label length if in Variable Length on page
150 Mode, or the first fixed length if in Fixed Length on page 150 Mode. The
length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characte
rs in increments of two. See "Set
Length 1" on
page 248 for more detailed programming instructions.
Select I 2 of 5 Length 1 Setting
To configure this feature, scan the ENTER/EXIT barcode
above, then the barcode at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
06 = Length 1 is 6 Characters
$CI2L1
~