User Manual

Enter/Exit Programming Mode Code 128
140 RIDA™ DBT6400
Code 128 Set Length 2
This feature specifies one of the barcode lengths for Code 128 Length Control
on page 138. Length 2 is the maximum label length if in Variable Length on
page 138 Mode, or the second fixed length if in Fixed Length on
page 138
Mode. Length includes the barcode’s data characters only.
The length can be set from 1 to 80 characters. A setting of 00 specifies to
ig
nore this length (only one fixed length). See "Set Length 2" on
page 249 for
more detailed programming instructions.
Select Code 128 Length 2 Setting
To configure this feature, scan the ENTER/EXIT barcode
above, then the barcode at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
80 = Length 2 is 80 Characters
$CC8L2
~