1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
123
GS1 DataBar Expanded Set Length 2
This feature specifies one of the barcode lengths for GS1 DataBar Expanded
Length Control on page 122. Length 2 is the maximum label length if in Vari-
able Length on page 122 Mode, or the second fixed length if in Fixed Length on
page 122 Mode. Length includes the barcode’s data characters only.
The length can be set from 1 to 74 characters. A setting of 00 specifies to
ig
nore this length (only one fixed length). See "Set Length 2" on
page 249 for
more detailed progr
amming instructions.
Select GS1 DataBar Expanded Set Length 2 Setting
To configure this feature, scan the ENTER/EXIT barcode
above, then the barcode at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
74 = Length 2 is 74 Characters
$CXBL2
~