BHS AND REDS INSTALLATION MANUAL
48
6
6.4 REDS PARAMETER CONFIGURATION
1. Disconnect the Protecting SC6000 Controller from its PWO (CAB-SC6003 and CAB-
SC6013).
2. Completely configure the Working SC6000 Controller as follows:
a. The Lonworks Network is already pre-configured for BHS Kits. If not using a BHS Kit,
configure the Lonworks Network using Network Wizard in Genius™. All Slaves will
automatically be configured in PackTrack™ Operating Mode. See par. 4.2 and the
SC6000 Help On Line for details.
b. Configure all Scanners for Code Selection, and send them the configuration. See par.
4.3.1.
c. Perform PackTrack Calibration and Mirror Calibration on all the scanners. See
relative sub-paragraphs under 4.3 and par. 5.4.
d. Configure the Redundancy Parameters on the SC6000 as described in par. 6.4.1.
e. Configure the SC6000 for Code Selection, Data Formatting and all the necessary
parameters. See par. 4.4
f. Send the configuration to the Working Controller with Options + Environmental
Parameters as follow: Genius> Menu Bar> Device Menu> Send with Options> select
Environmental Parameters> OK.
NOTE
Wait for the system to respond. The Working Controller is ready when the
Net Mask appears on the SC6000 display.
Perform the DARP™ procedure as described in the SC6000 Reference
Manual.
g. Save the configuration on the PC.
3. Power down the system, disconnect the Working Controller from its PWO and connect
the Protecting Controller to its PWO, power up the system again.
4. Configure the Protecting Controller as described in par. 6.4.2.
NOTE
Wait for the system to respond. The Protecting Controller is ready when the
message Protecting/Stand by appears on the SC6000 display.
Perform the DARP™ procedure as described in the SC6000 Reference
Manual.
5. Power down the system, connect the Working Controller to its PWO and Power up the
system again.
NOTE
Both SC6000s must have the SAME Software Release and the SAME
Configuration.
NOTE
In case of SC6000 replacement for a REDS configuration, after
substituting the compact Flash and powering up the system (as described in
the SC6000 Reference Manual), wait for the system to come up completely
then power down the system and then power up again.