Installation manual
REDUNDANT SYSTEMS
43
6
Normal Package Detecting (preferred)
Figure 31 - PS Mounting (Over Under)
The first possibility is to put the two photocells one above the other as show in the picture
above.
This is the easiest and preferred way because the PS Line parameters and the PackTrack
origin XYZ=0 are equal for both SC6000s. In this case it is not possible to detect lower packs
with both photocells because they are at different heights, one over the other.
Small Package Detecting
Figure 32 - PS Mounting (Side by Side)
If lower packages must be detect, it is possible to mount the two photocells side by side as
show in the picture above.
In this way it is possible to detect lower packs with both photocells because they are at the
same height, but there is a different position along the Y coordinate between the two
SC6000s. In this case the Scanners PackTrack Calibration must be taken from the Working
photocell, see the coordinate origin XYZ=0 on the picture above, and the following
parameters must be set:
SC6000 Working -> Operating Modes -> PS Line (mm) = 0
SC6000 Protecting -> Operating Modes -> PS Line (mm) = positive value
PS Working
PS Protecting
XYZ=0