Installation manual

BHS AND REDS INSTALLATION MANUAL
38
5
NOTE
The Mirror Calibration MUST be executed using a barcode having 1 mm.
resolution (test chart).
If the calibration error value exceeds 1 S press Calibrate. If the value after calibration still
exceeds 1 S the scanner needs checking.
5.5 RETRIEVING INFORMATION IN CASE OF TROUBLE
Various detailed diagnostic information is available on the system to help troubleshoot the
most common problems. It is important to collect and forward such information to the
Datalogic T&L TSS Dept. for internal analysis.
5.5.1 Packtrack Debug Message TX
It is possible to configure the SC6000 to transmit messages concerning the system
functioning which are useful for debugging the system particularly during commissioning.
From the Genius™ Diagnostics folder, tick the PackTrack Debug Message Tx parameter
and select a PackTrack Debug Message Target from the related listbox.
The debug messages can be observed through a terminal connected to the selected
transport and logged to a file (i.e. through the Genius™ built-in terminal).
5.6 DL-STAT (GENIUS™ ADD-ON)
DL-Stat is used to perform maintenance on any reading station. It provides a simple
graphical interface to easily manage the statistics available for 8KA family and SC6000
devices (readings, label position, errors and many other useful values). By comparing old
and new data it is possible to understand if one or more scanners are decreasing in reading
rate or increasing on errors. The collected data can be stored to file for later analysis.
From Genius™ click the icon in the upper toolbar to activate DL-Stat.
5.7 DL-NET (GENIUS™ ADD-ON)
The health of the whole scanner network may be affected by the malfunction of a single
reader connected to it. In addition, incorrect wiring or damaged cables may produce network
congestion under particular situations. DL-Net collects and shows information and statistics
about the scanner network useful for monitoring the network traffic details.
From Genius™ click the icon in the upper toolbar to activate DL-Net.
NOTE
The internal statistic counters can store up to 65535 counts, so be careful
that these counters do not overlap in the event of long DL-Net sessions.