Installation manual
SOFTWARE CONFIGURATION
33
4
4.5 SC6000 KEYPAD AND DISPLAY OVERVIEW
The SC6000 keypad allows entering a menu to select various essential information windows
shown on a compact a 20 x 4 LCD.
Reading Performance window
Number of the processed parcels
Good Read Rate
No Read Rate
Multiple Read Rate
Reading Mask window
Nodes that performed a reading of the enabled codes.
“*“ : the node read a barcode
“–“ : the node did not read a barcode
Conveyor Speed window
Conveyor speed shown in mm/sec and ft/min
I/O Status window
Status of the digital input/output
System Info window
Information about the software release
Last Codes & Read Mask window
Last read code
List of nodes that performed a reading
Statistics (No Read rate, Partial Read rate, Multiple Read rate) calculated on the last 100
codes or in continuous mode depending on the parameter selection
Alarms window
Alarms generated by the SC6000 or by the network listed in order of their priority
Warning LED
A failure message causes the Warning LED to be on (fixed), while a warning message
causes the LED to blink.