Installation manual
BHS AND REDS INSTALLATION MANUAL
32
4
4.4 SC6000 APPLICATION PROGRAM CONFIGURATION
From Genius™, configure all the necessary parameters for the SC6000:
CODE DEFINITION
Code Label Settings > expected Code Symbologies and Label Lengths (same as
those selected on the scanner)
Code Combination
No Read/Multiple Read strings
OPERATING MODES
Operating Mode Selection = PackTrack
Encoder Step = 252
PS Line = 0
Distance From PS Line to TX Line = depends on Customer requirements
Transmission Edge = depends on Customer requirements
Window Dimension (* see below)
Minimum Pack Length (* see below)
Minimum Distance Between Packs (* see below)
DATA COMMUNICATION SETTINGS
Data Format
Main serial Port parameters
Ethernet / Profibus parameters
Genius™ online parameter help is available by pressing F1 while the parameter is selected.
NOTE (*): the default settings for these parameters work well when sorting parcels of regular
shape (boxes). In several applications most parcels have a shape that can create confusing
presence sensor signal (glitches) resulting in false “packs too short” or “pack too close”
errors as shown in the picture below.
200 mm
Glitch or "pack too short"
Resulting PS signal
In case of Airport stations, make the following changes:
Operating Modes Minimum Distance Between Packs (mm) = 200
Operating Modes Minimum Pack Length (mm) = 200
Operating Modes Window Dimension (mm) = 200
When finished with the parameters, send the configuration to the SC6000 and wait for
restart.