SOFTWARE CONFIGURATION
23
4
4 SOFTWARE CONFIGURATION
Once mechanical installation, wiring and cabling are completed, software configuration is
necessary, according to the following basic steps:
1. Reader’s Network configuration
2. DS/DX reader calibration and parameter’s configuration
3. SC6000 application program parameter’s configuration
The SC6000 controller in combination with the DATALOGIC GENIUS
TM
configuration
program makes the network set up and maintenance very easy and quick. In addition
Genius™ allows scanner configuration and calibration of all the controlled scanners.
4.1 GENIUS OVERVIEW
Genius™ runs on any Windows-based PC. INSTALLER level is needed when installing the
system. Run command: “..\Program Files\Datalogic\Genius\Genius.exe" /L installer STHD.
Genius™ connects to the SC6000 controller through its main/aux serial port or Ethernet port
via TCP/IP (51235). The SC6000 works as bridge between the PC and the controlled
scanners for configuration, calibration, software update and maintenance procedures.
Figure 25 - Genius™Main Window
Command menus
MAIN toolbar area
TOOLS toolbar area menus
ADD-ONs toolbar area menus
Parameters explorer area
Device explorer area
Connection status area
Access level area