Installation manual
CONNECTIONS
17
3
3.3 READER CONNECTIONS
The readers are connected to the “LonWorks” network through 4 x “8K” connectors available
on the PWO. Each “8K” connector supports a branch, each branch is made up of 4 readers
maximum (total 16 readers max). Connection between scanners and PWO is performed by
CAB-810X. The possible lengths are 1.2m, 2.5m and 5m.
The readers must be connected alternatively as shown in the figures below, this allows
reading on all sides even if one of the branches is not working.
Install a “Terminator” plug BTK-8100 at the open end of the last scanner of each branch.
Each unused connector (8K series connectors) requires a terminator BTK-8100, to provide
correct termination to the LonWorks network.
Figure 18 - Reader Connections for T-Label Stations
Figure 19 - Reader Connections for L-Label Stations
3.3.1 Checking Reader Connections
Apply power to the array and check that the “POWER ON” LED (green) and the “NETWORK”
(red) LED are both ON and that the encoder LED flashes ON and OFF as the encoder wheel
is rotated.
Figure 20 - Checking Reader LED Indicators
POWER ON
PHASE ON
ENCODER
TX DATA
NETWORK
CAB-8105
CAB-8102
CAB-8105
CAB-8102
CAB-8105
CAB-8105
CAB-8102
CAB-8105
BTK-8100
BTK-8100
2 x BTK-8100
TERMINATORS
A
C
E
G
B
D
F
H
E
A
B
F