TROUBLESHOOTING GUIDE
Problem Suggestions
Reading:
Not possible to read the
target barcode (always
returns No Read)
Check synchronization of reading pulse with object to read:
Is the scan line correctly positioned?
Place barcode in the center of scan line and run TEST MODE
(selectable by Genius™ as an Operating Mode). If you still have
trouble, check the following:
Is the reading distance within that allowed (see reading
diagrams)?
Is the Tilt angle too large?
Is the Skew angle less than 10° (direct reflection)?
Choose the CODE tab and enable different code types
(except Pharmacode). LENGTH = Variable.
Is the Bar Code quality sufficient?
If you had no success, try to perform the test using the
BARCODE TEST CHART included with the product.
Communication:
Device is not
transmitting anything to
the host
Is the serial cable connected?
Is the correct wiring respected?
Are serial host settings equivalent to the serial device
setting?
If using C-BOX 100, be sure the RS485 termination switch is
positioned to OFF.
Communication:
Data transferred to the
host are incorrect,
corrupted or incomplete
In the Genius™ program select the DATA FORMAT tab and
check for values of HEADER, TERMINATOR, SEPARATOR,
FILL CHARACTERS
Also check the CODE FIELD LENGTH value.
Are the COM port parameters correctly assigned?
Communication:
Always returns the
Reader Failure
Character (<BEL> char
as default)
Contact your local Datalogic office or Datalogic Partner or
ARC, because either a Motor or Laser failure has occurred.
Note the exact model and Serial Number of the device.
How do I obtain my
units’ serial
numbers?
The device’s serial number is printed on a label that is affixed
to the body of the reader.
Serial numbers consist of 9 characters: one letter, 2
numbers, and another letter followed by 5 numbers.
62