Installation manual
DS2100N REFERENCE MANUAL
3
The main and auxiliary ports are connected as shown in the figure below.
4
Master Slave#1 Slave#2 Slave#n
2
1
Terminal
Host
3
Main Serial Interface (RS232 or RS485 Full-Duplex or RS485 Half-Duplex)
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for On-Line Mode)
ID-NET™ (up to 16 devices)
Figure 40 – ID-NET™ M/S Synchronized Layout
4
Master Device#1 Device#2 Device#n
2
1
Terminal
Host
3
Main Serial Interface (RS232 or RS485 Full-Duplex or RS485 Half-Duplex)
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for On-Line Mode)
ID-NET™ (up to 32 devices, max network extension of 1000 m)
Figure 41 – ID-NET™ M/S Multidata
NOTE
The auxiliary serial interface of the slave scanners can be used in Local Echo
communication mode to control any single scanner (visualize collected data)
or to configure it using the Genius™ utility or the Genius™ based Host Mode
programming procedure.
The termination resistors of the RS485 bus must be installed inside the first
and last C-BOX.
46