Code Verifier
If the DS2100N is used as a Code Verifier, it is possible to indicate to the scanner what code
to store as the verifier code by means of an external hardware input.
The Code Verifier parameter must be enabled and the configuration parameters to allow
correct Code Type reading must be saved to the scanner in order to read the verifier code.
The next read code will be stored as the verifier code in the scanner's
non-volatile (Flash) memory.
3.3.6 Outputs
Two general purpose outputs are available.
These outputs can only be connected as open
collector configurations. The following pins are present on the 25-pin connector of the
scanner:
Pin Name Function
8 OUT1+ Output 1 +
11 OUT2+ Output 2 +
22 OUT1- Output 1 -
12 OUT2- Output 2 -
The meaning of the two outputs OUT1 and OUT2 can be defined by the user (No Read,
Right or Wrong). Refer to the Genius™ Help On Line.
By default, OUT1 is associated with the No Read event, which activates when the code
signaled by the external trigger is not decoded, and OUT2 is associated with the Right event,
which activates when the code is correctly decoded.
These outputs are both level and pulse configurable.
USER INTERFACE
OUT+
8/11
22/12
OUT-
DS2100N
V
ext 40 Vdc max.
C
E
Figure 34 - Output Open Collector Connections
V
CE
max = 30 Vdc
I max = 40 mA continuous