Installation manual
DS2100N REFERENCE MANUAL
3
EXTERNAL TRIGGER INPUT
EXTERNAL TRIGGER
DS2100N
Signal
18
19
VS
9
25
GND
Ground
V
EXT TRIGA
EXT TRIGB
V
CC
~
~
+
-
Figure 31 - External Trigger NPN using DS2100N power
EXT TRIG A
18
19
DS2100N
EXTERNAL TRIGGER
Signal
V
Vext 30 Vdc max.
EXT TRIG B
V
CC
~
~
+
-
Figure 32 - External Trigger NPN command using external power
EXTERNAL TRIGGER
DS2100N
18
19
VS
9
25
GND
Ground
V
Signal
EXT TRIGA
EXT TRIGB
V
CC
~
~
+
-
Figure 33 - Input PNP Command Using DS2100N Power
Electrical Features: Maximum voltage: 30 Vdc
Maximum current: 12 mA
An anti-disturbance hardware filter is implemented on the External Trigger input
(< 5 milliseconds delay).
IN2 INPUT NPN Only
IN -
VS
DS2100N
INPUT
Signal
V
GND
Ground
10
25
+ 5V
Input 2 NPN command