Installation manual

DS2100N REFERENCE MANUAL
1
C-BOX 100/150 Pinout for DS2100N
The table below gives the pinout of the C-BOX 100/150 terminal block connectors. Use this
pinout when the DS2100N reader is connected by means of the C-BOX 100/150:
C-BOX 100/150 Terminal Block Connectors
Power Outputs
1, 3, 5 VS 21 OUT 1+
2, 4, 6 GND 22 OUT 1-
7, 8 EARTH GROUND 23 OUT 2+
20, 40 Reserved 24 OUT 2-
Inputs
25 NC
27 EXT TRIG A (polarity insensitive) 26 NC
28 EXT TRIG B (polarity insensitive)
Auxiliary Interface
29 NC 35 TX AUX
30 IN2- 37 RX AUX
31, 33 NC
ID-NETâ„¢
32, 34 NC 36 ID-NET-
39 GND 38 ID-NET+
Main Interface
RS232
RS485 Full-
Duplex
RS485 Half-Duplex
20 mA C.L.
(with
INT-30 only)
11, 15 TX 232 TX 485+ RTX 485+
12, 16 RTS 232 TX 485- RTX 485-
17 RX 232 *RX 485+
18 CTS 232 *RX 485-
10, 14,
19
SGND SGND SGND
9, 13
RS485 Cable
Shield
RS485 Cable Shield
see INT-30
instructions
* Do not leave floating, see par. "RS485 Full-Duplex Interface" for connection details.
CAUTION
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
2