Specifications

INSTALLATION
3
MATRIX
USER INTERFACE
Vext
30 Vdc max
+
-
I
Load
V
Out
Figure 53 - Open Collector Output Connection
The electrical features of the three outputs are the following:
OUTPUT I
Load
V
Out
Open 0 mA 30 Vdc Max
Closed 10 mA 1.8 Vdc Max
P
D
= V
Out
× I
oLoad
= 170 mW Max.
39