Specifications
Matrix-2000™ Reference Manual
3
3.3.2 Main Serial Interface
The signals relative to the following serial interface types are available on the 25-pin
connector:
RS232 (default setting)
RS485 FULL DUPLEX
RS485 HALF DUPLEX
The main serial interface type and its parameters (baud rate, data bits, etc.) can be
defined by the user via VisiSet™ software. The RS485 half duplex is automatically set
whenever MUX32 communication protocol is enabled. For more details refer to the
"Communication" folder in the VisiSet™ Help On Line.
Details regarding the connections and use of the main interface selection are given in the
next paragraphs.
RS232 Interface
The opto-isolated RS232 interface can be used for Point-to-Point, Pass Through or
Master/Slave connections. When it is connected to the host computer it allows both
transmission of code data and reader configuration by VisiSet™.
The following pins of the 25-pin connector are used for RS232 interface connection:
Pin Name Function
2 TX232 Transmitted data
3 RX232 Received data
4 RTS232 Request to send
5 CTS232 Clear to send
7 GND_ISO Main opto-isolated reference ground
30