Specifications

Matrix-2000™ Reference Manual
1
CAUTION
If Matrix-2000™ is connected to a C-BOX 3x0/4x0 through its 25-pin
connector, then the Matrix-2000™ 9-pin Auxiliary port connector cannot be
used for communication (i.e. configuration through VisiSet™). In this case
use the Auxiliary port 9-pin connector inside the C-BOX 3x0/4x0.
STEP 2 – MOUNTING AND POSITIONING THE SYSTEM
1. To mount the Matrix-2000™, use the mounting bracket to obtain the most suitable
position for the reader as shown in the figures below.
Figure 2 - Positioning with Mounting Bracket
2. When mounting the Matrix-2000™ take into consideration these three ideal label position
angles: Pitch or Skew 10° to 20° and Tilt 0°, although the reader can read a code at any Tilt
angle.
Minimize Assure at least 1 Minimize
Figure 3 – Pitch, Skew and Tilt Angles
3. Refer to the Reading Features in chp. 7 to determine the distance your reader should be
positioned at.
2