Instruction manual
MATRIX 200™ REFERENCE MANUAL
5
INPUT 2 CONNECTI
ONS USING EXTERNAL POWER
Matrix 200™
INPUT DEVICE
Vext 30 Vdc max.
I2A
6
10
I2B
V
CC
~
~
+
-
V
Signal
Figure 80 - PNP Input 2 Using External Power
Matrix 200™
INPUT DEVICE
Vext 30 Vdc max.
I2A
6
10
Signal
V
I2B
V
CC
~
~
+
-
Figure 81 - NPN Input 2 Using External Power
5.7 OUTPUTS
Two opto-coupled general purpose outputs are available on the 25-pin connector. The
meaning of the two outputs Output 1 and Output 2 can be defined by the user. They are
typically used either to signal the data collection result.
The pinout is the following:
Pin Name Function
9 Vdc Power Supply input voltage +
8 O1+ Configurable digital output 1 - positive pin
22 O1- Configurable digital output 1 - negative pin
11 O2+ Configurable digital output 2 - positive pin
12 O2- Configurable digital output 2 - negative pin
7 GND Power Supply input voltage -
The electrical features of the two outputs are the following:
V
CE
max = 30 Vdc
I max = 40 mA continuous; 130 mA pulsed
By default, Output 1 is associated with the Partial Read and No Read events, which activates
when the code(s) signaled by the external trigger are not decoded, and Output 2 is
associated with the Complete Read event, which activates when all the selected codes are
correctly decoded.
66