Instruction manual

25-PIN CABLE ELECTRICAL CONNECTIONS
5
5.3.3 RS485 Half-Duplex Interface
NOTE
This interface is provided for backward compatibility. We recommend using
the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts.
The RS485 half-duplex (3 wires + shield) interface is available for polled communication
protocols.
It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. 6.5) exploiting
a proprietary protocol b
ased on polled mode called MUX32 protocol, where a master device
polls slave devices to collect data.
The following pins of the 25-pin connector are used for RS485 half-duplex communication:
Pin Name Function
2 RTX+ RS485 Receive/Transmit Data (+)
4 RTX- RS485 Receive/Transmit Data (-)
7 GND Ground
RTX+
2
RT
X
-
4
RTX485 +
RTX485 -
7
GND
MULTIPLEXER
RS485REF
Matrix 200™
1
Chassis
Figure 66 - RS485 Half-duplex Connections
This interface is forced by software when the protocol selected is MUX32 protocol.
In a Multiplexer layout, the Multidrop address must also be set via serial channel by the
VisiSet™ utility or by the Host Programming Mode.
55