Instruction manual
25-PIN CABLE ELECTRICAL CONNECTIONS
5
5 25-PIN CABLE ELECTRICAL CONNECTIONS
5.1 25-PIN CONNECTOR
The Matrix 200™ reader is equipped with a 25-pin male D-sub connector for connection to
the power supply, serial interfaces and input/output signals. The details of the connector pins
are indicated in the following table:
13
2514
1
Figure 60 - 25-pin Male D-sub Connector
25-pin D-sub male connector pinout
Pin Name Function
13, 9 Vdc Power supply input voltage +
25, 7 GND Power supply input voltage -
1 CHASSIS Cable shield connected to chassis
18 I1A External Trigger A (polarity insensitive)
19 I1B External Trigger B (polarity insensitive)
6 I2A Input 2 A (polarity insensitive)
10 I2B Input 2 B (polarity insensitive)
8 O1+ Output 1 +
22 O1- Output 1 -
11 O2+ Output 2 +
12 O2- Output 2 -
20 RX Auxiliary RS232 RX
21 TX Auxiliary RS232 TX
23 ID+ ID-NET™ network +
24 ID- ID-NET™ network -
14, 15, 16, 17 NC Not Connected
Pin Name RS232
RS485
Full-Duplex
RS485
Half-Duplex
2 TX TX+ RTX+
3 RX *RX+
4 RTS TX- RTX-
5
MAIN INTERFACE
(SW SELECTABLE)
CTS *RX-
* Do not leave floating, see par. 5.3.2 for connection details.
In order to meet EMC requirements:
connect the reader chassis to the plant earth ground by means of a flat copper braid
shorter than 100 mm;
for direct connections, connect the main interface cable shield to pin 1 of the 25-pin
connector.
51